Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
Search Results "Floor Slope"
-
11B-404.2.7 Door and gate hardware
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
Drinking Fountain Scoping for Exterior Sites
In the final rule, scoping has been clarified as applying to units provided at "exterior sites," in addition to those installed on floors....
-
Example: Historic House Museum
The town develops plans to alter the facility to provide physical access to the first floor....
-
Islands: ADA Standard Section 406.7
Section 406.7 covers the current ADA Standards for islands.
-
11B-406.6 Islands
Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it...
-
11B-406.6 Islands
Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it...
-
1(3)(a)(i)
(i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes...
-
K4
If built-in food, drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor space is...
-
1(3)(a)
(a) There is an elevator connecting the parking area with the dwelling units on a ground floor....
-
Jamb Signage
...are all elevator jambs provided with signs placed on both sides designating the floor with 2" minimum height raised letters and Braille characters centered at 60" above the finish floor...
-
5e.
Are signs mounted on both sides of the elevator hoistway door opening that designate the floor with 2-inch minimum-height raised letters and Braille characters centered at 60 inches above...
-
11B-1005.1 Accessible routes
length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
-
Gangways
Gangways A gangway is a variable-sloped pedestrian walkway linking a fixed structure or land with a floating structure....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
§ 36.304(d)(3)
Such measures include, for example, providing a ramp with a steeper slope or widening a doorway to a narrower width than that mandated by the alterations requirements....
-
R304.2.3 Flared Sides
Where a pedestrian circulation path crosses the curb ramp, flared sides shall be sloped 10 percent maximum, measured parallel to the curb line. Advisory R304.2.3 Flared Sides....
-
Thresholds at Doorways [4.13.8]
Thresholds above ¼ inch must be beveled with a slope no greater than 1:2....
-
4.33.3* PLACEMENT OF WHEELCHAIR LOCATIONS
EXCEPTION: Accessible viewing positions may be clustered for bleachers, balconies, and other areas having sight lines that require slopes of greater than 5 percent....
-
11B-303.3 Beveled
Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2....
-
11B-1005.1 Accessible routes
length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
-
Free-Standing Overhead Lifts
Free-Standing Overhead Lifts Another type of overhead lift is supported from a frame that rests on the floor....
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
§ 38.159(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches (1220 mm)....