(a) Ramps: Curb ramps and interior or exterior ramps to be constructed on sites or in existing buildings or facilities where space limitations prohibit the use of a 1:12 slope or less may...
Search Results "Building Permit"
-
4.1.6(3)(a) Ramps
-
A4.3.10 Egress
Because people with disabilities may visit, be employed or be a resident in any building, emergency management plans with specific provisions to ensure their safe evacuation also play an...
-
4.1.4(11) RESIDENTIAL
Residential occupancy includes, among others, the use of a building or structure, or portion thereof, for sleeping accommodations when not classed as an institutional occupancy....
-
1. SCOPING CONSIDERATIONS FOR ALTERATION PROJECTS
This applies when either 1) existing elements are altered or 2) new elements, up to and including new buildings, are added....
-
1128A.1 General
Note: See Sections 1101A “Application” and 1102A “Building Accessibility” for dwelling units required to comply with this division....
-
1128A.1 General
Note: See Sections 1101A “Application” and 1102A “Building Accessibility” for dwelling units required to comply with this division....
-
6. Wheelchairs and Other Power-Driven Mobility Devices
Wheelchairs (and other devices designed for use by people with mobility impairments) must be permitted in all areas open to pedestrian use....
-
241 and 612 Saunas and Steam Rooms
Doors are not permitted to swing into the clear floor or ground space for the accessible bench....
-
6. Wheelchairs and Other Power-Driven Mobility Devices
Wheelchairs (and other devices designed for use by people with mobility impairments) must be permitted in all areas open to pedestrian use....
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 _|Slope|_ is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum...
-
11B-1009.2.7 Operation
The lift shall be stable and not permit unintended movement when a person is getting into or out of the seat. [2010 ADAS] 1009.2.7 Operation. ...
-
Baby Changing Tables
Commenters noted that baby changing tables should not be permitted in accessible compartments since they can interfere with access....
-
F221.2.3.1 Horizontal Dispersion
2nd and 3rd quartile of a row is insufficient to accommodate the required number of companion seats and wheelchair spaces, the additional companion seats and wheelchair spaces shall be permitted...
-
404.2.3 Clear Width
In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear width shall be permitted for the latch side stop. 2....
-
604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
604.5 Grab Bars (Exception 2)
604.5 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed at water closets in residential dwelling units required to provide mobility features provided...
-
608.3 Grab Bars (Exception 2)
608.3 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed in shower compartments in residential dwelling units required to provide mobility features...
-
206.7.6 Guest Rooms and Residential Dwelling Units, F206.7.6 Guest Rooms and Residential Dwelling Units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with 806.2 or residential dwelling units required...
-
607.4 Grab Bars (Exception 2)
607.4 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed at bathtubs in residential dwelling units required to provide mobility features provided...
-
402.2 Speech-Output Enabled
Where speech output cannot be supported due to constraints in available memory or processor capability, ICT shall be permitted to conform to 409 in lieu of 402.2. 4....
-
711.3.1 Through penetrations
Exception: Where the penetrating items are steel, fer- rous or copper pipes or steel conduits, the annular space between the penetrating item and the fire-resistance- rated wall shall be permitted...
-
Was the carrier correct in asking me to take a seat other than a bulkhead seat in the emergency exit row?
The carrier was within its rights to refuse to permit you to sit in the bulkhead seat with your service animal, because the service animal may have blocked access to the emergency exit....
-
408.4.1 Car Dimensions and Doors
Cars that provide a clear width 51 inches (1295 mm) minimum shall be permitted to provide a clear depth 51 inches (1295 mm) minimum provided that car doors provide a clear opening 36 inches...
-
11B-502.3.4 Location
Access aisles shall be permitted to be placed on either side of the parking space except for van parking spaces which shall have access aisles located on the passenger side of the parking...