Although one might loosely characterize these conditions as "disabilities" in relation to the aspirations of the particular individual, the disabilities reached by title III are limited...
Search Results "Maximum Reach Depth"
-
III-2.1000 General
-
Operating Hardware
Single-lever handle that is easy to reach and operable with one hand ...
-
11B-220.1 Automatic teller machines and fare machines
Accessible ATMs, including those with speech and those that are within reach of people who use wheelchairs, must provide all the functions provided to customers at that location at all times...
-
11B-505.6 Gripping surface
People with disabilities, older people, and others benefit from continuous gripping surfaces that permit users to reach the fingers outward or downward to grasp the handrail, particularly...
- Cavity Sliders USA Inc. CL100 ADA Privacy Lever Lock for Pocket Doors
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
R302.4 Passing Spaces
Where the clear width of pedestrian access routes is less than 1.5 m (5.0 ft), passing spaces shall be provided at intervals of 61 m (200.0 ft) maximum....
-
7(2)(b)(v)
The top of the fixture rim is a maximum height of 2'10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2'3" above the floor....
-
11B-608.3.3 Alternate roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. FIGURE 11B-608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS...
-
10.3.1(4)
Such signs shall be placed in uniform locations at entrances within the transit system to the maximum extent practicable....
-
703.2.5 Character Height
Character height measured vertically from the baseline of the character shall be 5/8 inch (16 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter "I"....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
Dimensional Tolerances [3.2]
Recommendation: It is good practice to avoid specifying precisely to the maximum or minimum where possible so that achieved dimensions fall within ADAAG requirements....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
1.1.2 Walks
This includes surfaces with a maximum slope of 1:20 (5%), such as a walk, parking area, or a portion of a driveway that is also used for a walking surface....
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
Flush Controls on Toilets
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
C204.1 General (Section-by-Section Analysis)
Similarly, these types of products do not typically provide transactional outputs covered by proposed 409. 407.12 Reach Height and 408 Display Screens....