The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and the transition from the station platform...
Search Results "Maximum Extent Practicable"
Commonly Searched Documents
-
§ 38.83(b)(8) Platform entrance ramp
-
§ 38.95(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the centerline of...
-
11B-502.6.4.1
The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking...
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
Re: SCOTT JOHNSON v. STARBUCKS CORPORATION - AMICUS BRIEF
requirements in the ADA regulations such as: 1) 36.211 - The obligation to maintain accessible features in an operable working condition. 2) 36.302(a) - The obligation to modify policies, practices...
-
IV. ALTERATIONS AND NEW CONSTRUCTION
To the extent, after construction commences, the construction plans change in a manner impacting the approved ADA Plans, Olympia shall submit the changed plans to the ILA to be reviewed...
-
4.3.8 Operating forces
For other types of operable parts, the upper limit for operating force should be retained at a maximum of 5 lbf (22 N) to accommodate 95% of the sample....
-
Accessibility - Flatness and Lippage
Mortar setting beds for concrete pavers and paving slabs Joint width between paving units with chamfers (See Figure I) Maximum 3/8 in. (10 rom) - The surface of the mortared joint...
-
2.2.3 Functional Reach
Use of the electromechanical probe required manually digitizing the 3-D location of the maximum reach point after the cylinder was positioned (Figure 2‒3)....
-
405.2 Slope (Exception 2), 405.6 Rise (Exception)
The running slope of ramp runs must not be steeper than 1:12 and any ramp rise must be 30 inches maximum....
-
704.8 Allowable area of openings
The maximum area of unprotected or protected openings permitted in an exterior wall in any story shall not exceed the values set forth in Table 704.8....
-
Toilet Paper Dispensers
The provisions for toilet paper dispensers at section 604.7 of the 2010 Standards require the dispenser to be located seven inches minimum and nine inches maximum in front of the water closet...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
-
Features of Accessible Parking Spaces
Access aisle width is at least 60 inches, must be at the same level and the same length as the adjacent parking space(s) it serves, maximum slope in all directions is 1:48, and access aisle...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter 0.059 (1.5 mm) to 0.063 (1.6 mm)...
-
11B-703.3.1 Dimensions and capitalization
TABLE 11B-703.3.1 BRAILLE DIMENSIONS MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter...
- Spinal Cord Injury Association of Washington (SCIAW)
-
11B-407.2.1.4 Location
Responding cars are programmed for maximum efficiency by reducing the number of stops any passenger experiences....
-
1009.2.1 Pool Lift Location
Where multiple pool lift locations are provided, no more than one pool lift shall be required to be located in an area where the water level is 48 inches (1220 mm) maximum....
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum. The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level....
-
703.4.1 Height above Finish Floor or Ground
characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum...
-
Section 4.26.2
Handrail gripping surfaces with a non-circular cross section must have a perimeter dimension of 4 inches to 6 ¼ inches, and a cross section dimension of 2 ¼ inches maximum....