The display screen must be visible from a point located 40 inches (1015 mm) above the center of the clear floor space in front of the automated kiosk....
Search Results "Clear Width at Turn"
Commonly Searched Documents
-
§ 27.71(k)(7)(i) Visibility
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
Scoping [4.1.2(4), 4.1.3(3)]
Requirements in 4.5 apply to accessible routes and spaces, including ramps, elevators, platform lifts, and clear floor space....
-
11B-707.7.1 Visibility
The display screen shall be visible from a point located 40 inches (1016 mm) above the center of the clear floor space in front of the machine....
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
The 21 inches minimum width is based on the ideal chair width recommended in Architectural Graphic Standards for auditorium seating....
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1-1/4 in to 1-1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface....
-
Seeger et al.
Both unoccupied and occupied dimensions of device width and length were measured as well as a set of other basic dimensions....
-
§ 38.159(b)(7) Platform gaps
Any openings between the platform surface and the raised barriers shall not exceed 5/8 inch (16 mm) in width....
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
11B-406.5.12 Detectable warnings
The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum...
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
- Diadema 80 Interior Wall Sconce by Hampstead
- HEWI Range 180 Door Hardware
- Earbuds with Microphone (BE9229)
- Headphones with Microphone (BE9133)
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
406.6 Diagonal Curb Ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
11B-904.4.2 Forward approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a forward approach to the counter. [2010 ADA Standards] 904.4.2 Forward Approach....
- Mockett HK2B-SSS Triple Coat Hook
-
11B-404.2.9 Door and gate opening force
controlled on both the interior and exterior sides of the doors by sensing devices, push plates, vertical actuation bars or other similar operating devices complying with Sections 11B-304 _|Turning...