Priority 4: Additional Access - Drinking Fountains, Public Telephones & Fire Alarms
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
., at least 32 inches nominal clear width, with no requirements for maneuvering clearances and hardware. (See 56 FR 9487-9488, March 6, 1991, or 24 CFR Ch. I, Subch. A, App. III.)...
-
5.8.2.3 Overall Knee and Toe Clearance
The overall knee and toe space should be increased to a minimum of 28 inches....
-
(c) Thresholds at patio, deck or balcony doors
The final Guidelines provide that exterior deck, patio, or balcony surfaces should be no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed...
-
§ 35.151(g)(1)
(1) In stadiums, arenas, and grandstands, wheelchair spaces and companion seats are dispersed to all levels that include seating served by an accessible route;...
-
Parking
Total Spaces in Parking Lot Required Number of Accessible Parking Spaces 1 to 25 1 van space 26 to 50 1 standard space + 1 van space 51 to...
-
a. Knee and Toe Clearance
The MDE Advisory Committee recommended increasing the overall knee and toe space to a minimum 28 inches deep....
-
2. Equipment Clearances for Breast Platforms
The proposed rule included a requirement that 17 inches minimum and 25 inches maximum of the 48-inch wheelchair space depth include knee and toe clearance....
- Willoughby Industries 2240 AquaDeck Lavatory Deck Angled Front
-
Recreational Boating Facilities
Word Fillable Form (1.6MB) Word Non-Fillable Form (1.5MB) PDF Non-Fillable Form (0.8MB)
-
Lavatory and Accessory Layout by Terry Salo, Architect, CASp
Lavatory and Accessory Layout by Terry Salo, Architect, CASp NOTE: The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper...
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum....
-
11B-812.6.4 Drive-up
Vehicle spaces serving drive-up EVCS shall be 204 inches (5182 mm) wide minimum and shall not be required to have an adjacent access aisle....
-
11B-812.6.4 Drive-up
Vehicle spaces serving drive-up EVCS shall be 204 inches (5182 mm) wide minimum and shall not be required to have an adjacent access aisle....
-
5.8.2.3 Overall Knee and Toe Clearance Recommendation
5.8.2.3 Overall Knee and Toe Clearance Recommendation The Committee recommends increasing the overall knee and toe space to 28 inches minimum....
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair space....
-
11B-604.8.1.1 Size
The minimum space required in toilet compartments is provided so that a person using a wheelchair can maneuver into position at the water closet....
-
11B-812.8.1 Four or fewer
Where four or fewer total EVCS are provided, identification with an International Symbol of Accessibility (ISA) shall not be required.
-
1.9.1.1.2
1.9.1.1.2 All buildings, structures and facilities that are leased, rented, contracted, sublet or hired by any municipal, county or state division of government, or by a special...
-
1.9.1.1.2
1.9.1.1.2 All buildings, structures and facilities that are leased, rented, contracted, sublet or hired by any municipal, county or state division of government, or by a special...
-
11B-812.8.1 Four or fewer
Where four or fewer total EVCS are provided, identification with an International Symbol of Accessibility (ISA) shall not be required.
-
M303.2.6 Edge Protection (Section-by-Section Analysis)
(Significant Changes – Edge Protection), the final rule requires platforms with wheelchair spaces that are raised more than 1½ inches in height to provide a minimum 2-inch-high edge protection...