pedestrians, the final rule requires the signs to include information on the length of the trail or trail segment; surface type; typical and minimum tread width; typical and maximum running slope...
Search Results "Sloped Area"
-
Trailhead Signs
-
1014.2.1 Transfer Access
The surface of the clear ground space is required to be firm and stable, and to slope not steeper than 1:48 in any direction....
-
Installation of Test Surfaces
The installation steps were: 1) Excavate area 380 mm (15 in.) in depth with a minimum of 1% grade to ensure proper drainage....
-
WHEELCHAIR
This definition does not apply to Federal wilderness areas; wheelchairs in such areas are defined in section 508(c)(2) of the ADA, 42 U.S.C. 12207(c)(2)....
-
WHEELCHAIR
This definition does not apply to Federal wilderness areas; wheelchairs in such areas are defined in section 508(c)(2) of the ADA, 42 U.S.C. 12207(c)(2)....
-
4(4)
Thresholds and changes in level at these locations are beveled with a slope no greater than 1:2....
-
H5
[ADA Standards §§ 4.1.6(3)(d)(ii), 4.13.8] Yes No NA If No, replace threshold with one with beveled sides or add a sloped insert....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
D5. Raised Threshold
[ADA Stds 4.1.6(3)(d)(ii), 4.13.8] Yes _____ No _____ If No, replace threshold with one with beveled sides or add sloped insert to threshold....
-
11B-812.3 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Mezzanine
An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the level or...
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
D. What Does Title II of the ADA Require with Respect to Curb Ramps at Pedestrian Crossings?
Some public entities have extensive responsibility for the highways, streets, roads, pedestrian crossings, and walkways in their area, but most public entities have at least limited responsibility...
-
Findings
Within 12 months of installation, playground sites in the sample with the loose fill EWF were found to have the greatest number of deficiencies, such as excessive running slope, cross slope...
-
3. Review the Research Findings About Accessibility Issues for Play Surfaces
Deficiencies (excessive running slope, cross slope, change in level, or openings) for PIP, TIL and HYB began to emerge 24-36 months after installation....
-
Picnic Tables
All new picnic table installations must comply with requirements for accessible seating spaces, table clearance, slope, and surface....
-
1010.1.4 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
-
1010.1.4 Floor elevation
Landings shall be level except for exterior landings, which are permitted to have a slope not to exceed 0.25 unit vertical in 12 units horizontal (2-percent slope)....
-
403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with 505. Advisory 403.6 Handrails....
-
1009.2.2 Seat Location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48....
-
403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with 505. Advisory 403.6 Handrails....
-
Grade
This may be expressed as the percentage of change in elevation (grade) or as a ratio of vertical distance to horizontal distance (running slope)....