The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
Search Results "Accessible Means of Egress"
-
11B-411.2.1.3.1 Keypad call console arrangement
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-233.3.3 Additions
required to comply with Sections 11B-233.3.1.1 _|Residential Dwelling Units with Mobility Features|_ and 11B-233.3.1.2 _|Residential Dwelling Units with Adaptable Features|_ shall be on an accessible...
-
11B-233.3.3 Additions
required to comply with Sections 11B-233.3.1.1 _|Residential Dwelling Units with Mobility Features|_ and 11B-233.3.1.2 _|Residential Dwelling Units with Adaptable Features|_ shall be on an accessible...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
11B-223.1 General
The lack of a design requirement does not mean that covered entities are not required to provide services to people with disabilities where accessible patient bedrooms or resident sleeping...
-
11B-223.1 General
The lack of a design requirement does not mean that covered entities are not required to provide services to people with disabilities where accessible patient bedrooms or resident sleeping...
-
15. ADA Coordinator for the Pedestrian Right of Way
(b) A list of the Program Access Improvements performed or implemented since the last report (including an itemization of the types or categories of Program Access Improvements performed...
-
4. Applicability
Applicability The SNPRM: We proposed to apply the WCAG 2.0 Web site accessibility standard to U.S. and foreign carrier primary Web sites that market (i.e., advertise or sell) air transportation...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
-
Construction and Maintenance Practices
When employees understand how their work can affect accessibility, they can look for ways to improve accessibility....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
- Door King Inc. 1802 and 1802-EPD Electronic Programmable Directory Telephone Entry System
-
§ 36.302(e)(1) Reservations made by places of lodging
A public accommodation that owns, leases (or leases to), or operates a place of lodging shall, with respect to reservations made by any means, including by telephone, in-person, or through...
-
§ 36.302(f)(1) General
A public accommodation shall modify its policies, practices, or procedures to ensure that individuals with disabilities can purchase tickets for accessible seating during the same hours,...
-
4.4.2 Head Room
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
4.4.2 HEAD ROOM
If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in (nominal dimension), a barrier to warn blind or visually-impaired persons shall be provided (...
-
11B-604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
-
11B-604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
-
III-9.2000 Relationship to State and local enforcement efforts
Some, but not all, of these include accessibility requirements....
-
Short Hikes and Interesting Features
Sometimes it makes sense to provide a short section of trail meeting the technical requirements for accessibility on a trail that would otherwise be totally exempted from the technical requirements...