Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
Search Results "Stair Signage"
-
11B-703.5.9 Line spacing
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
IV. Priority Seating Signs and Other Signage
Priority Seating Signs and Other Signage...
-
505.10.3 Bottom Extension at Stairs
505.10.3 Bottom Extension at Stairs....
-
11B-504.5 Nosings
Additionally, because it is possible to catch the top of one’s shoe on the underside of stair nosings, access compliance regulations require the underside of nosings to be free of abrupt...
-
11B-504.5 Nosings
Additionally, because it is possible to catch the top of one’s shoe on the underside of stair nosings, access compliance regulations require the underside of nosings to be free of abrupt...
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
505.10.2 Top Extension at Stairs
505.10.2 Top Extension at Stairs....
- Access Board: Tactile Sign Clear Floor Space
-
Egress Signage
Various signage requirements specific to certain spaces and elements have been relocated for simplicity and ease of reference to section 216....
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters indicating elevator car controls shall not be...
-
11B-703.5.6 Height from finish floor or ground
11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
Required Compliance [§210]
Compliance is required for all stairs on required egress routes, including those comprised of a single riser....
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
505.10.3 Bottom Extension at Stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
Signage
Signage: a....
- Innerface Clearview Interior Signage
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
1023.9 Stairway identification signs
The signage shall also state the story of, and the direction to, the exit discharge and the availability of roof access from the interior exit stairway and ramp for the fire department....
- Access Board: Tactile Sign Visual Requirements
-
Treads and Risers [4.9.2], Nosings [4.9.3]
Uniformity is important not only between steps but along each step; curved stairs, where the width of each tread varies, do not meet this requirement....
-
11B-505.10 Handrail extensions
Handrail gripping surfaces shall extend beyond and in the same direction of stair flights and ramp runs in accordance with Section 11B-505.10....