Launch Ramps Without Boarding Piers
-
Clear Width: ADA Standard Section 405.5
Section 405.5 covers the current ADA Standards for the clear width requirements of ramps.
- Figure 405.9.1 Extended Floor or Ground Surface Edge Protection – Drawing from the U.S. Access Board
-
Section 35.151(i) Curb Ramps (Section-by-Section Analysis)
The current § 35.151(e) on curb ramps has been redesignated as § 35.151(i). ...
-
Section 35.151(i) Curb ramps (Section-by-Section Analysis)
Section 35.151(i) Curb ramps (Section-by-Section Analysis) Section 35.151(e) on curb ramps in the 1991 rule has been redesignated as § 35.151(i)....
-
1.2.5 Ramps
1.2.5 Ramps. When overall running slope and cross slope for accessible ramps are measured according to Sections 1.1.11 a recommended tolerance for these slopes is +0.5%....
-
R304 Curb Ramps and Blended Transitions (Section-by-Section Analysis)
R304 Curb Ramps and Blended Transitions (Section-by-Section Analysis)...
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADAS] 405.9 Edge Protection. ...
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADAS] 405.9 Edge Protection....
-
11B-405.9 Edge protection
Edge protection complying with Section 11B-405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. [2010 ADA Standards] 405.9 Edge Protection....
-
6f. Ramp Handrails
Are the handrails mounted between 34 and 38 inches above the ramp surface? [ADA Stds 4.8.5] Yes _____ No _____...
-
D) Curb Ramps at Intersections
When walkways cross a curb at intersections, a ramp or sloped surface is needed. The title II regulations set requirements for curb ramps at intersections....
-
405.9 Edge Protection
Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS: 1....
-
405.9 Edge Protection
Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS: 1....
-
405.9 Edge Protection
Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS: 1....
-
405.9 Edge Protection
Edge protection complying with 405.9.1 or 405.9.2 shall be provided on each side of ramp runs and at each side of ramp landings. EXCEPTIONS: 1....
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings at perpendicular curb ramps shall extend 36 inches (914 mm) in the direction of travel....
-
DSA Drawing 11B-406-10 Parallel Curb Ramp with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
- Lift-U® Fold-Out Rising Floor Ramp
-
235.3 Boarding Piers at Boat Launch Ramps
235.3 Boarding Piers at Boat Launch Ramps....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
§ 38.23(c)(1) Design load
Ramps 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp distributed over an area of 26 inches by 26 inches, with a safety factor of at least 3 based...
- Simplified Building Concepts ADA Handrail