(b) Employment entrance examination. A covered entity may require a medical examination (and/or inquiry) after making an offer of employment to a job applicant and before the...
Search Results "Licensing Exam"
Commonly Searched Documents
-
1630.14(b)
-
Pre-employment Inquiries and Medical Examinations
Pre-employment Inquiries and Medical Examinations An employer may not ask a job applicant about the existence, nature, or severity of a disability. Applicants may be asked about...
-
M302.1 General
Diagnostic equipment that supports patients in a seated position shall comply with M302. EXCEPTION: Where weight scales contain wheelchair spaces complying with M303 and also...
-
M302.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a seated position must comply with the technical requirements of proposed section M302. As discussed in...
-
§1630.13(a) Pre-employment examination or inquiry
(a) Pre-employment examination or inquiry. Except as permitted by §1630.14, it is unlawful for a covered entity to conduct a medical examination of an applicant or to make inquiries...
-
§1630.14(b) Employment entrance examination
(b) Employment entrance examination. A covered entity may require a medical examination (and/or inquiry) after making an offer of employment to a job applicant and before the...
-
§1630.14(c) Examination of employees
(c) Examination of employees. A covered entity may require a medical examination (and/or inquiry) of an employee that is job-related and consistent with business necessity. A covered...
-
M301.3.1 Transfer Supports
Transfer surfaces required by M301.2 shall provide transfer supports and shall comply with M305.2.
-
M305.5 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M301.3 Supports
Transfer supports, leg supports, and reclining surfaces shall comply with M301.3.
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
-
M305.5 Head and Back Support (Section-by-Section Analysis)
As discussed above in Section V.C.3.c (Section-by-Section Analysis – M301.3.3) and Section V.C.7.c. (Section-by-Section Analysis – M302.3.3), the technical requirements for head and...
-
M301.3 Supports (Section-by-Section Analysis)
This is an introductory section. An editorial change was made to this section as a result of the change in M301.3.2, described below, to replace the word “stirrups” with the term...
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The MDE NPRM proposed to require transfer supports to be provided for use with transfer sides on diagnostic equipment used by patients in the supine, prone, or side-lying position,...
-
M301.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a supine, prone, or side-lying position must comply with the technical requirements of proposed section M301....
-
M301.3.3 Head and Back Support (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed to place the requirements for head and back support for diagnostic equipment used by patients in the supine, prone, or side-lying position...
-
5.3.2 Transfer Sides Recommendations for M301
5.3.2 Transfer Sides Recommendations for M301 Description: The transfer side provision requires the transfer surface to be located to provide options to transfer onto the short...
-
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position.
-
M301.3.1 Transfer Supports
Transfer supports shall be provided for use with the transfer sides required by M301.2.3 and shall comply with M305.2.
-
M301.3 Supports
Transfer supports, stirrups, and reclining surfaces shall comply with M301.3.
-
M301.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M305 Supports
[See subsections ...]
-
M305 Supports (Section-by-Section Analysis)
M305 in the final rule provides the technical requirements for transfer supports, standing supports, leg supports, and head and back supports. Transfer supports are required for...
-
M305 Supports
[See subsections ...]