Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
Search Results "Leg Supports"
Commonly Searched Documents
-
M305.2.7 Clearance
-
M305.2.4 Cross Section
Transfer supports shall have a cross section complying with 305.2.4.1 or 305.2.4.2....
-
M305.2.1 Location (Section-by-Section Analysis)
The Committee recommended requiring one support on the opposite side of the transfer side regardless of whether it was a transfer support or positioning support....
-
M305.2.5 Surface Hazards
Transfer supports and surfaces adjacent to transfer supports shall be free of sharp or abrasive components and shall have eased edges....
-
Service Animal Issues
Another important issue that a number of commenters raised concerned “emotional support animals.”...
-
Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar with Leg
Requires the Premium User plan or above. (Login or upgrade your account!)
-
M305.2.1 Location
Transfer supports shall be located within reach of the transfer surface and shall not obstruct transfer onto or off of the surface when in position....
-
Conclusion
During this second phase of the independent wheelchair transfer study, platform transfers with and without grab-bars and a backrest and two-step transfers were evaluated. The study...
- Service and Companion Animal Owners: Know Your Rights!
-
Implication for Standards and Design
Each phase involved a highly customized transfer station iteratively developed with scientific, expert and consumer input to support the goals of the project. ...
-
M305.2.3 Height
During use, the tops of transfer support gripping surfaces shall be 6 inches (150 mm) minimum and 19 inches (485 mm) maximum higher than the top of the associated uncompressed transfer surface...
-
M305.2.5 Surface Hazards (Section-by-Section Analysis)
The proposed rule did not provide any specific restrictions regarding surface hazards around the transfer supports....
-
(1) Transfer Surface Location for Diagnostic Equipment Used in the Supine, Prone, or Side-lying Position
This revision to provide options for two types of transfer surfaces necessitated adding additional technical criteria addressing transfer surface size (M301.2.3) and transfer supports (M305.2...
- Mockett TLRAL27 Roma Series Adjustable Table Leg
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
- Mockett TLKNB27 Original Kyros Leg 5" Base
-
Examples of access:
Exam table that lowers to 17-19 inches from the floor Many people find these tables easier to use. There are many ways to help people get access. See the [images]...
-
ADA Requirements - Service Animals
U.S. Department of Justice Civil Rights Division Disability Rights Section Service Animals The Department of Justice published revised final regulations implementing the...
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches...
- Mockett TLEL3 Electrically Driven Adjustable Table Legs
-
d. Unobstructed Transfer
Six of the eleven commenters who responded to this question supported permitting equipment parts to extend up to three inches horizontally beyond the edge of the transfer surface....
- Big John Toilet Support & Short Swivel Support informational video
- Big John Toilet Support & Short Swivel Support 7.5" to 14" Installation Video
- HEWI Hinged Support Rail Duo