STONE LEG PICNIC TABLE Contact Santa Fe NE for construction drawings ETA Editor's Note Stone Leg Picnic Table drawings: Click here to view/download CAD file | Click...
Search Results "Leg Supports"
Commonly Searched Documents
-
Stone Leg Picnic Table
-
Steel Leg Picnic Table
STEEL LEG PICNIC TABLE Contact Santa Fe NE for construction drawings ETA Editor's Note Steel Leg Picnic Table drawings: Click here to view/download CAD file | Click...
- Project LETS (Let's Erase the Stigma)
- A Complete Guide to Service, Therapy and Emotional Support Dogs
-
Transfer Protocols
For each transfer, participants were asked to position themselves next to the platform as they normally would to prepare for a transfer. The angle of their WMD relative to the front...
-
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
Documenting Exceptions
Recording and retaining documentation of determinations of the basis for exceptions for any outdoor recreation feature is a good practice. These records will become very valuable...
- Big John Toilet Support & Short Swivel Support
-
Study Objectives
The purpose of this study was to examine independent transfers to and from a WMD and a simple platform, with and without the use of grab bars and/or a backrest, and transfers between...
-
Gripping Surface Cross Section and Clearances M301, M302, and M305.2
Gripping Surface Cross Section and Clearances M301, M302, and M305.2 Gripping surface for transfer supports shall be free of sharp or abrasive elements and shall have rounded edges per...
- Service Animals for Business Owners
-
Figure M5: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and 304 Diagnostic Equipment for Use by a Patient in a Standing Position (Mammography Machine Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. ...
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support....
-
M305.2.8 Fittings (Section-by-Section Analysis)
The MDE NPRM proposed to require that transfer supports not rotate in their fittings (proposed M305.2.3). Five commenters addressed this provision....
-
M305.2.2 Length
The length of transfer supports shall comply with M305.2.2.1 or M305.2.2.2....
-
3.1 Getting Weighed
Accessible scales are important to quality health care for people with disabilities. An accessible scale allows a wheelchair user to roll onto the platform of the scale. Someone who...
-
M305.2.3 Height (Section-by-Section Analysis)
The MDE Advisory Committee supported adding a requirement setting the height of transfer supports within the range described in question 20 in the MDE NPRM preamble, of 6 inches minimum...
-
M305.2.6 Gripping Surfaces (Section-by-Section Analysis)
The proposed rule did not provide any specific requirements regarding gripping surfaces on transfer supports....
-
M305.2.1 Location
Transfer supports shall comply with M305.2.1.1 or M305.2.1.2 and shall be located 1 ½ inches (38 mm) maximum measured horizontally from the plane defined by the nearest edge of the transfer...
-
M305.2.6 Gripping Surface
Transfer support gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings....
-
M305.2.4 Cross Section (Section-by-Section Analysis)
The proposed rule did not provide specific requirements for the cross section of transfer supports....
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer....