These data depict the reaching abilities of power chair users represented as the percentage of users expected to reach to a target location in the forward reach direction for a...
Search Results "Holding Cell"
Commonly Searched Documents
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Power Chair
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Scooter
These data depict the reaching abilities of scooter users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Scooter
These data depict the reaching abilities of scooter users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach...
-
Chapter 8: Special Rooms, Spaces, and Elements
assembly areas (802), dressing, fitting, and locker rooms (803), kitchens and kitchenettes (804), medical care and long-term care facilities (805), transient lodging guest rooms (806), holding...
-
Dimensions and Capitalization: ADA Standard Section 703.3.1
Measurement Range Minimum in Inches Maximum in Inches Dot base diameter 0.059 (1.5 mm) to 0.063 (1.6 mm) Distance between two dots in the same cell...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
These data depict the reaching abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Power Chair
These data depict the reaching abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or...
-
11B-604.5 Grab bars
In detention or correction facilities, grab bars shall not be required to be installed in housing or holding cells that are specially designed without protrusions for purposes of suicide...
-
Turning Space [§304]
facilities dressing, fitting, and locker rooms transient lodging guest rooms dwelling units (all rooms on an accessible route) patient bedrooms holding...
-
11B-703.3.1 Dimensions and capitalization
adjacent cells1 0.300 (7.6 mm) Dot height 0.025 (0.6 mm) to 0.037 (0.9 mm) Distance between corresponding dots from one cell...
-
604.5 Grab Bars
In detention or correction facilities, grab bars shall not be required to be installed in housing or holding cells that are specially designed without protrusions for purposes of suicide...
-
211 Drinking Fountains
Exceptions: In detention or correctional facilities, drinking fountains only serving holding or housing cells not required to comply with 232 shall not be required to comply with 211....
-
407.4.7.1.3 Symbols
Table 407.4.7.1.3 Elevator Control Button Identification Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP Three cells...
- Georgia-Pacific Dixie Products SmartStock® Classic Medium-weight Polystyrene Knife Dispenser- Holds 120 Utensils Video
- Plantronics AME-Q90D Ameriphone TTY
-
11B-407.4.7.1.3 Symbols
407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP Three cells...
-
407.4.7.1.3 Symbols
407.4.7.1.3 Elevator Control Button Identification Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP Three cells...
-
11B-407.4.7.1.3 Symbols
407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP Three cells...
-
11B-407.4.7.1.3 Symbols
Alarm AL"AR"M Four cells Door Open OP"EN" Three cells Door Close...
-
407.4.7.1.3 Symbols
407.4.7.1.3 Elevator Control Button Identification Control Button Tactile Symbol Braille Message Emergency Stop "ST"OP Three cells...
-
604.5 Grab Bars
In detention or correction facilities, grab bars shall not be required to be installed in housing or holding cells that are specially designed without protrusions for purposes of suicide...