A clear floor or ground space complying with Section 11B-305 shall be provided....
Search Results "Clear Opening"
Commonly Searched Documents
-
11B-811.2 Clear floor or ground space
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
11B-403.5.2 Clear width at turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1219 mm) wide, clear width shall be 42 inches (1067 mm) minimum approaching the turn, 48...
-
§ 38.95(b)(7) Platform gaps
Any openings between the lift platform surface and the raised barriers shall not exceed 5/8 inch wide....
-
Section 36.303(g)(10)
Section 36.303(g)(10) in the final rule provides that “[t]his section does not require the use of open movie captioning as a means of compliance with paragraph (g), even if providing closed...
-
1018.4 Clear Width
The clear width of beach access routes shall be 60 inches (1525 mm) minimum....
-
6.6 Clear Width
The clear width of beach access routes shall be 60 inches (1525 mm) minimum....
-
1018.4 Clear Width
The clear width of beach access routes shall be 60 inches (1525 mm) minimum....
-
D. Captioning and Video Description Generally
Open movie captions are sometimes referred to as "burned in" or "hardcoded" captions....
-
1011.2 Clear Ground Space
This section requires a clear ground space to be provided at outdoor constructed features and includes specific provisions for the size and location (1011.2.1), surface (1011.2.2), slope...
-
1008.2.4 Clear Width
Accessible routes connecting play components shall provide a clear width complying with 1008.2.4....
-
1008.2.4 Clear Width
Accessible routes connecting play components shall provide a clear width complying with 1008.2.4....
-
Clear Floor Space
The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant.
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
CLEAR FLOOR SPACE
CLEAR FLOOR SPACE. [DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
§ 38.83(b)(7) Platform gaps
Any openings between the lift platform surface and the raised barriers shall not exceed 5/8 inch wide....
-
§ 38.23(b)(7) Platform gaps
Any openings between the platform surface and the raised barriers shall not exceed 5/8 inch in width....
- Visitability
-
Clear Floor or Ground Space and Turning Space
This guide explains requirements in the ADA Standards for clear floor or ground space and turning space....
-
307.5 Required Clear Width
307.5 Required Clear Width. Protruding objects shall not reduce the clear width required for accessible routes....
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
Exterior/ Fire Doors
Considering that closing force is 60% efficient, a 15 Ib maximum for opening force provides 9 lb for closure and latching, which may be sufficient for most doors....