11B-305.7 Maneuvering clearance
-
404.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
403.5.2 Clear Width at Turn
403.5.2 Clear Width at Turn....
-
5.1.6 Clear Floor or Ground Space
A clear floor or ground space at least 36 inches (915 mm) by 48 inches (1220 mm) shall be provided parallel at the elevated entrance to the camp shelter....
-
404.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of 5 lbf. See Standards § 4.13.11(2)(b). ee....
-
Door Closers [4.13.10]
Door Closers [4.13.10] Because it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be...
-
811.2 Clear Floor or Ground Space
811.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided....
-
General: ADA Standard Section 404.1
Section 404.1 of the ADA Standards covers information in the current ADA Standards for doors, doorways, and gates that are part of an accessible route.
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADAS] 404.2.9 Door and Gate Opening Force. ...
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADAS] 404.2.9 Door and Gate Opening Force....
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
Clear space
Clear space: A grid 72 inches long by 90 inches wide was used to facilitate the recording of space requirements for each WMD user (Figure 1)....
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
§ 36.303(g)(10)
(10) This section does not require the use of open movie captioning as a means of compliance with paragraph (g) of this section, even if providing closed movie captioning for digital movies...
-
1132A.6 Closer-effort to operate doors
1132A.6 Closer-effort to operate doors. Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
1132A.6 Closer-effort to operate doors
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to...
-
403.5.2 Clear Width at Turn
Where the accessible route makes a 180 degree turn around an element which is less than 48 inches (1220 mm) wide, clear width shall be 42 inches (1065 mm) minimum approaching the turn, 48...
-
811.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-