(i) Costs associated with providing an accessible entrance and an accessible route to the altered area, for example, the cost of widening doorways or installing ramps;...
Search Results "Adjusted Construction Cost"
Commonly Searched Documents
-
Sec.36.403(f)(2)(i)
- Lynx Grills Inc. 30” Grill 1 ProSear Burner & 1 Stainless Steel Burner with Rotisserie (L500ADAR)
- Lynx Grills Inc. 36” Grill 1 ProSear Burner & 2 Stainless Steel Burners with Rotisserie (L600ADAR)
-
Scoping Requirements
The scoping requirements for outdoor constructed features are explained in the sections of the standards that contain the scoping requirements for camping and picnic facilities, viewing...
-
M301.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision that was added to the final rule in conjunction with the new requirement of a low height range in M301.2.1...
-
3.2.2.3. High Accessibility Baseline
The estimated costs of the final rule under the High Accessibility baseline are estimated as a sensitivity analysis presented in Section 4.2.2....
-
§ 35.151(b)(4)(iv)(B)(4)
(4) Accessible telephones;
-
§ 35.151(b)(4)(iv)(B)(1)
(1) An accessible entrance;
-
Section 35.151(c) Accessibility Standards for New Construction and Alterations (Section-by-Section Analysis)
Comments discussing the costs and benefits of the proposed standards have been considered and taken into account by the Department's regulatory impact analysis. ...
-
Construction and Maintenance Practices
Even the best universal design can be ruined, often unintentionally, by construction or maintenance practices that turn accessible design features into barriers....
-
1001.1 Scope
Unless otherwise modified or specifically addressed in Chapter 10, all other requirements in this document apply to the design and construction of recreation facilities. ...
-
Phasing in Play Areas
Phasing in Play Areas When play areas are constructed in phases, they must continue to meet the play area guidelines throughout construction. ...
-
1001.1 Scope
Unless otherwise modified or specifically addressed in Chapter 10, all other requirements in this document apply to the design and construction of recreation facilities....
-
F244.3 Outdoor Constructed Features in Common Use and Public Use Areas
Where provided in common use and public use areas that serve camping units with mobility features, at least 20 percent, but not less than one, of each type of outdoor constructed feature...
-
§8.25(a)(1)
(1) The requirements of §8.22 shall apply to all newly constructed public housing and multi-family Indian housing....
-
3.2 Projects with Adjusted Construction Costs Above the Valuation Threshold
3.2 Projects with Adjusted Construction Costs Above the Valuation Threshold: The 20-percent disproportionate cost limitation does not apply to projects with adjusted construction costs above...
-
Designed and Constructed for First Occupancy (Preamble, Section-by-Section Analysis)
Designed and Constructed for First Occupancy According to paragraph (a)(2), a facility is subject to the new construction requirements only if a completed application for a building permit...
-
5.1.2 Transfer Surface High Height
The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches....
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25 inches....
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
Breast Platform [M303.4.1]
Breast Platform [M303.4.1] Recommendation: The final recommendation for the minimum height of the breast platform is 26 inches from the floor to the top of the breast platform....
-
M303.4.1 Breast Platforms
The height of the breast platform shall be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when in use by a patient seated in a wheelchair.
-
Can access be provided after construction based on need?
Access required by the ADA Standards must be put in place and ready for use as part of construction....
-
4.1.1(1) General
All areas of newly designed or newly constructed buildings and facilities required to be accessible by 4.1.2 and 4.1.3 and altered portions of existing buildings and facilities required...