Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
Search Results "Seat Location"
-
11B-305.7 Maneuvering clearance
-
11B-232.2.1.4 Technically infeasible
Where it is technically infeasible to locate a substitute cell within the same prison site in compliance with Section 11B-232.2.1.3, a substitute cell shall be provided at another prison...
-
§382.65(b)
(b) If a passenger asks you to provide an on-board wheelchair on a particular flight, you must provide it if the aircraft being used for the flight has more than 60 passenger seats, even...
-
3. Desk clear floor space
Desk clear floor space: If provided, desks and writing tables need to have a 30-inch by 48-inch clear floor space that extends 19 inches under the desk and any fixed seat needs to be removable...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
3.11 Tinseltown, 651 Medford Center, Medford, Oregon
3.11 Tinseltown 651 Medford Center, Medford, Oregon - In Auditorium 6, the four (4) wheelchair spaces shall be located one row further back in the auditorium from their current location...
-
Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)]
The IBC (2003) permits one accessible means of egress from: wheelchair seating in assembly areas with sloped floors where the common path of travel meets aisle requirements for...
-
11B-604.8.1.5 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
11B-409.1 General
Accessibility scoping requirements for elevators and lifts are located in Sections 11B-206.6 and 11B-207.6 [sic]; technical requirements are located in Sections 11B-407, 11B-408, 11B-409...
-
11B-409.1 General
Accessibility scoping requirements for elevators and lifts are located in Sections 11B-206.6 and 11B-207.6 [sic]; technical requirements are located in Sections 11B-407, 11B-408, 11B-409...
-
11B-604.8.1.5 Grab bars
A side-wall grab bar complying with Section 11B-604.5.1 shall be provided and shall be located on the wall closest to the water closet....
-
3.10 Cinemark 22, 2600 West Avenue I, Lancaster, California
location...
-
36 Inch Wide Stalls
This stall is specifically designed for people who have difficulty walking or standing from a seated position....
-
Space Allowance and Reach Ranges [4.2]
For example, the specified height of toilets and shower seats (17-19 inches) approximates the standard seat height of manual wheelchairs to facilitate transfer....
-
Road Racing Wheelchairs
Typically, a low seating position is preferred to increase stability and decrease resistance....
-
M101.2 Application
patient positions that the equipment is designed to support: • Equipment used by patients in a supine, prone, or side-lying position (see M301); • Equipment used by patients in a seated...
- Behavioral Health Integration Capacity Assessment Introductory Webinar
-
11B-217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each location...
-
Hospitals: ADA Standard Section 217.4.6
Section 217.4.6 covers scoping requirements in the current ADA Standards for TTYs in hospitals.
-
11B-217.4.6 Hospitals
Where at least one public pay telephone is provided serving a hospital emergency room, hospital recovery room, or hospital waiting room, at least one public TTY shall be provided at each location...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction...
-
1i
Are all of the small showers free of curbs or lips greater than 1/2" high at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...