Verbal announcements must announce each floor a car stops at but not each floor passed....
Search Results "Floor Designation"
Commonly Searched Documents
-
Car Position Indicators [4.10.13]
- CRL-Blumcraft® Panic Handles 08 7100
-
Self-Service Storage
Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on a self-service...
-
Standards: ADA Standard Section 1991
This of the ADA Standards covers the definition of the 1991 ADA Standards.
-
[ADA Title II §35.104] 2010 Standards
[ADA Title II §35.104] 2010 Standards means the 2010 ADA Standards for Accessible Design, which consist of the 2004 ADAAG and the requirements contained in §35.151....
-
11B-234.4.1 Load and unload areas
Where load and unload areas serving existing amusement rides are newly designed and constructed, the load and unload areas shall comply with Section 11B-1002.3....
-
11B-810.1.1 Vehicle boarding
Stations shall not be designed or constructed so as to require persons with disabilities to board or alight from a vehicle at a location other than one used by the general public....
- Cybex Total Access Row/Rear Delt Exercise Machine
-
Free-Standing Overhead Lifts
Free-Standing Overhead Lifts Another type of overhead lift is supported from a frame that rests on the floor....
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
§ 38.159(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches (1220 mm)....
-
1(3)(a)(i)
(i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes...
-
K4
If built-in food, drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor space is...
-
1(3)(a)
(a) There is an elevator connecting the parking area with the dwelling units on a ground floor....
-
Edge Protection: ADA Standard Section 1005.3
Extending the deck of the fishing pier or platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs...
-
3306.2 Walkways
Walkways shall be accessible in accordance with Chapter 11A or 11B as applicable, and shall be designed to support all imposed loads, and the design live load shall be not less than 150...
-
Clear Space Evaluation
nlike [sic] the first phase of the transfer study, subjects in this study were not impeded by any obstacles on the floor that limited the manner of which they approached the transfer station...
-
Boat Slips: ADA Standard Section 1003.2.1
Where handrail extensions are provided on gangways or transition plates, the handrail extensions shall not be required to be parallel with the ground or floor surface. 7....
-
11B-1003.2.1 Boat slips
Another design solution would be to have two 40 foot (12 m) plus continuous gangways joined together at a float, where the float (as the water level falls) will stop dropping at an elevation...
- Cybex Total Access Arc Trainer
-
11B-238.2.3 Weather shelters
Where provided, weather shelters shall be designed and constructed so that a golf car can enter and exit the weather shelter and shall comply with Section 11B-1006.4....
-
217.2 Wheelchair Accessible Telephones
Table 217.2 Wheelchair Accessible Telephones Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible...
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach. ...