- Employs capacitance technology similar to star devices to operate low energy doors - Ideal installations include medical facilities, assisted living facilities, offices, clean rooms...
Search Results "Patient Room"
Commonly Searched Documents
- Hager Companies 6” Round ADA Actuator 2-659-0303
- inLOOP Commercial Use Product Line Digital 1600 Assistive Listening System
- Hager Companies 6” Round ADA Actuator 2-659-0307
- Hager Companies 4.75” Square ADA Actuator 2-659-0305
- Hager Companies 6” Round ADA Actuator 2-659-0304
- Hager Companies 4.75” Round ADA Actuator 2-659-0306
- Hager Companies 4.75” Square ADA Actuator 2-659-0308
- Brinks Home Security Alwood Keyed Entry Lever
- Landscape Forms Inc. Washington Square Bench Collection
-
4.4.3 Implications of Mammography Equipment Components
Lastly, the configuration of the positioning supports must provide enough flexibility for all patients to be able to reach and hold them....
-
COSTS TO LOWER MINIMUM TABLE HEIGHT
HEIGHT To be useful for its intended purpose, examination tables and chairs must maintain a high height of at least 32 inches, so that the health care provider has clinical access to the patient...
-
Websites
These websites may include, but are not limited to, patient web portals, e-prescriptions, and personal health tools....
-
4.16.6 Dispensers
Becket, indicated that nursing staff at Memorial Hospital of Martinsville and Henry County (Martinsville, VA), felt that 24" would provide sufficient space for staff and still permit a patient...
-
M102.1 Defined Terms (Section-by-Section Analysis)
Other commenters (manufacturers, medical associations, disability rights organizations, and an individual) suggested the following terms be defined: health care provider, breast platform, patient...
-
(1) Adjustability: Minimum High Transfer Height
Therefore, transfer surfaces that are adjustable to a 25-inch maximum during patient transfer accommodate most patients who use mobility devices....
-
2.4.1 Current Marketplace Dynamics
As part of designing for broader patient populations and delivery settings, new equipment designs incorporate patient and clinician usability considerations, such as adjustable table heights...
-
Reasonable Accommodation Process Illustrated
Suppose a Sack Handler position requires that the employee pick up fifty pound sacks and carry them from the company loading dock to the storage room, and that a sack handler who is disabled...
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-
8.2.2 Stimuli
Stimuli for the reverberation plus noise condition were recorded in three separate environments: a classroom, an auditorium, and a conference room....
-
III. FACILITIES COVERED BY THIS CONSENT DECREE
not limited to, the public entrances to the Hotel, the guest registration desk, the lobby, the public telephones, the public and employee restrooms, the elevators, the units, sleeping rooms...
-
11B-213.3.2 Water closets
ETA Editor’s Note: The 2016 CBC is more inclusive, requiring more accessible water closets in larger toilet rooms....
- Assisted Living Directory - Arizona Assisted Living Facilities & Senior Care
-
Self-Service Storage Facilities: ADA Standard Section 225.3
Section 225.3 covers scoping requirements in the current ADA Standards for self-service storage facilities.
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.