(2) Doorways at ends of cars connecting two adjacent cars, to the maximum extent practicable in accordance with regulations issued under the Federal Railroad Safety Act of 1970 (49 CFR parts...
Search Results "PSAP: Public Safety Answering Point"
Commonly Searched Documents
-
§ 38.113(a)(2)
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
11B-1003.3 Clearances
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
Building Directories
Answer: While the ADA Standards at 216 (see below) specifically exempt building directories from complying with the ADA, there is a requirement in the ADA's Title III Regulations at §36.303...
-
Section 1193.51 Compatibility [1193.41 in the NPRM] (Section-by-Section Analysis)
An infrared link can also provide a mechanism for providing access to the smaller, more advanced telecommunication devices and provide a safety net for products which are unable to incorporate...
-
Detectable Warnings
In response to concerns about the specifications, the availability of complying products, proper maintenance such as snow and ice removal, usefulness, and safety concerns, the Board, along...
-
Proceedings of: Workshop on Improving Building Design for Persons with Low Vision
Gupta to improve the performance of public and private buildings through excellence in design and operations....
-
11B-802.3.1 Alignment
The shoulder alignment point of the wheelchair space shall be measured 36 inches (914 mm) from the front of the wheelchair space....
-
802.3.1 Alignment
The shoulder alignment point of the wheelchair space shall be measured 36 inches (915 mm) from the front of the wheelchair space....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
802.3.1 Alignment
The shoulder alignment point of the wheelchair space shall be measured 36 inches (915 mm) from the front of the wheelchair space....
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders or other means of reaching the raised elements...
-
Rise [§405.6]
While intermediate landings offer resting points, they do not reduce the amount of effort that must be exerted to negotiate multiple runs....
-
11B-802.3.1 Alignment
The shoulder alignment point of the wheelchair space shall be measured 36 inches (914 mm) from the front of the wheelchair space....
-
11B-802.3.1 Alignment
The shoulder alignment point of the wheelchair space shall be measured 36 inches (914 mm) from the front of the wheelchair space....
-
What Consumers Should Know
Here are some things you should know: VRS providers must answer 80 percent of all VRS calls within 120 seconds....
-
General comments regarding safe harbor. (Section-by-Section Analysis)
Under the International Building Code, for example, an existing structure is generally grandfathered provided that the building meets a minimum level of safety. ...
-
7. Q: What about applicants with a history of illegal drug use? Do they have rights under the ADA?
If safety is asserted as a justification for such a policy, then the employer must be able to show that individuals excluded because of a history of drug addiction or treatment would pose...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Outdoor Recreation Access Routes in Viewing Areas [F246.4]
At viewing areas not located along trails, at least one ORAR must connect accessible parking spaces or other arrival points that serve the viewing area with accessible elements, spaces,...
-
Clearances [§403.5]
Clearances [§403.5] The minimum 36” continuous clear width of accessible routes can reduce to 32” at points, such as doorways, for a maximum distance of 24”....
-
§1193.51(d) TTY connectability
Products which provide a function allowing voice communication and which do not themselves provide a TTY functionality shall provide a standard non-acoustic connection point for TTYs....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Exterior Site Requirement: ADA Standard Section 217.4.4
Section 217.4.4 covers scoping requirements in the current ADA Standards for TTYs at exterior sites.