Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
Search Results "High Energy Door"
Commonly Searched Documents
-
410 Platform Lifts
-
1007.6.5 Identification
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign complying with ICC A117.1, stating: AREA OF REFUGE, and including the International...
-
1003.2.13.5.5 Identification
Each door providing access to an area of refuge from an adjacent floor area shall be identified by a sign complying with ICC A117.1, stating: AREA OF REFUGE, and including the International...
- ANSI
-
Uniform Federal Accessibility Guidelines (UFAS)
Section 4.1.3(7) of the ADA Standards tells you generally about doors in new construction....
- Boost Your Business - Chapter 9 - Restroom Clear Space
-
4.24.3 Knee Clearance
Knee clearance that is at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided underneath sinks....
-
4.24.3 KNEE CLEARANCE
Knee clearance that is at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided underneath sinks....
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side....
-
11B-1005.3 Edge protection
Extending the deck of the fishing pier or platform 12 inches (305 mm) where the 34 inch (865 mm) high railing is provided is an alternative design, permitting individuals using wheelchairs...
-
X. Designated Agencies
Department of Interior: Lands and natural resources, including parks and recreation, water and waste management, environmental protection, energy, historic and cultural preservation, and...
-
PUBLIC HOUSING
Examples that are not considered a public entity’s program to provide housing may include but are not limited to: density bonuses, the receipt of public funds for the installation of energy...
-
4.13.11(2)
(2) Other doors....
- Somfy Window Covering Controls and Intergration with myLink™ App
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
-
M303.4.1 Breast Platform Adjustability
Breast platforms shall be continuously adjustable from a low height of 26 inches (660 mm) to a high height of 42 inches (1065 mm) above the floor....
-
Side Partitions and Wing Walls
The bottom edge of panels or partitions must be 27” high maximum....
-
§ 38.23(c)(4) Ramp barriers
Each side of the ramp shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
11B-403.5.1 Clear width
The clear width for accessible routes to accessible toilet compartments shall be 44 inches (1118 mm) except for door-opening widths and door swings....
-
General: ADA Standard Section 803.1
Partitions and doors should be designed to ensure people using accessible dressing and fitting rooms privacy equivalent to that afforded other users of the facility....
-
3.3.6 Knee Clearance Height, minimum
Smaller individuals who have large thighs, those with high seats and scooter users also have high lap heights....
-
11B-206.4.1 Entrances and exterior ground floor exits
The 2013 CBC Section 1011.4 requires such a door to be identified by a tactile exit sign with the following words “EXIT STAIR DOWN” or EXIT STAIR UP”....
-
11B-206.4.1 Entrances and exterior ground floor exits
The 2016 CBC Section 1013.4 requires such a door to be identified by a tactile exit sign with the following words “EXIT STAIR DOWN” or EXIT STAIR UP”....