Storage elements shall comply with at least one of the reach ranges specified in Section 11B-308.
Search Results "Door Height"
Commonly Searched Documents
-
11B-811.3 Height
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
- Sargent LS8600 Low Profile Center and Top Latch Concealed Vertical Rods Exit Device
- Corbin Russwin Inc. ED3000 Series Crossbar Exit Device
- Corbin Russwin Inc. ED8000 Pushpad Exit Device
- Allegion Von Duprin 22 Series Exit Devices
- Yale 1800 Series Flatbar Exit Device
- Allegion Falcon 19 Series Exit Devices
- Allegion Falcon XX Series Cross Bar Exit Devices
- Yale 2100 Series Flatbar Exit Device
- TownSteel MRXL Grade 1 Mortise Lock with Ligature Resistant Rose Trim
- Allegion Von Duprin 98/99 Series Exit Devices
- Corbin Russwin Inc. FE6700 Storm Shutter Multi-Point Latching System
- Yale 6000 Series Commercial Exit Devices
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer.
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum.
-
M305.2.7 Clearance (Section-by-Section Analysis)
In the MDE NPRM, the Access Board did not provide any specific requirements for clearances around the transfer support. However, in the preamble to the MDE NPRM the Access Board...
-
M305.2.8 Fittings (Section-by-Section Analysis)
The MDE NPRM proposed to require that transfer supports not rotate in their fittings (proposed M305.2.3). Five commenters addressed this provision. Four of the commenters disagreed...
-
5.4.10 Transfer Support Fittings Recommendations for M301 and M302
5.4.10 Transfer Support Fittings Recommendations for M301 and M302 Description: To ensure safe and effective transfers, transfer supports must not rotate within their fittings...
-
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.10 Transfer Support Fittings for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The transfer supports shall not rotate when locked in place for patient...
-
III. CONCLUSION
For the foregoing reasons, neither Section 904.4.1 nor its exception requires clear counter space at sales and service counters subject to the ADA’s requirements.
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings.