PLUMBING/RESTROOMS Turning space within the room 11B-603 Door swing not in clear floor space of any fixture (except...
Search Results "Door Height"
-
Plumbing/Restrooms
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck. FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT...
-
1002.6.2 Transfer Height
1002.6.2 Transfer Height. The height of transfer device seats shall be 14 inches (355 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
11B-408.4.1 Car dimensions and doors
Car doors shall be positioned at the narrow ends of cars and shall provide 32 inches (813 mm) minimum clear width....
-
11B-408.4.1 Car dimensions and doors
Car doors shall be positioned at the narrow ends of cars and shall provide 32 inches (813 mm) minimum clear width....
-
Attachment I: Program Access in Existing Facilities
Attachment I: Program Access in Existing Facilities
-
M301.3.2 Leg Supports
Where stirrups are provided, leg supports shall also be provided and shall comply with M305.4.
-
M301.3.2 Leg Supports (Section-by-Section Analysis)
In the MDE NPRM, the Access Board proposed to place the requirements for stirrups on diagnostic equipment used by patients in the supine, prone, or side-lying position in M301. In...
-
M305.4 Leg Supports (Section-by-Section Analysis)
As discussed above in Section V.C.3.b (Section-by-Section Analysis – M301.3.2) and Section V.C.7.b (Section-by-Section Analysis – M302.3.2), the technical requirements for leg...
-
3. Getting Access to Medical Equipment
No access to medical equipment can prevent people from getting appropriate medical services. In a national survey of people with disabilities or activity limitations, wheelchair...
-
M301.3.2 Stirrups
Where stirrups are provided, they shall provide a method of supporting, positioning, and securing the patient’s legs.
-
1002.5.2 Transfer Height
1002.5.2 Transfer Height....
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The Committee considered anthropometric data from a research project that examined transfer experience with an adjustable height transfer surface....
-
Mirror Height
The ANSI A117.1‒2003 standard contains a new requirement that specifies a height of 35 inches maximum for accessible mirrors not located above a lavatory or counter top....
- Yale 7000 Series Exit Devices
- BEA Inc. Keyswitches Access Control Devices
-
Table Surface Height
Persons with disabilities considered the 34 inch maximum height too high for surfaces used for any length of time....
-
11B-704.4.1 Height
11B-704.4.1 Height. When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
-
Exam Tables and Chairs
Exam Tables and Chairs Traditional fixed-height exam tables and chairs (also called treatment tables or procedure tables) are too high for many people with a mobility disability to use...
-
1015.3 Height
Exceptions: For occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, guards on the open sides of stairs shall have a height not less than 34...