Hinges and other door mechanisms shall be permitted to protrude 4 inches (100 mm) maximum into the door opening clear width at or below 48 inches (1220 mm) in height measured from the lowest...
Search Results "Maximum Dimension"
-
T502.4 Doorways with Steps on Over-the-Road Buses
-
3. EXCLUSIONS
Nevertheless, since the intended use of such excluded facilities may change with time or in emergencies, compliance with these DoD Standards is recommended to the maximum extent that is...
-
2.1.2.3 New York State Standards
Given a 1000 Hz signal at a level equal to the long-time average level of speech, the average value of the magnetic field should be 100 mA/meter +/- 3 dB between 100 to 8000 Hz, with a maximum...
-
11B-703.7.2.6.3 Unisex toilet and bathing facilities
The vertices of the triangle shall be located ¼ inch (6.4 mm) maximum from the edge of the circle....
- BEA Inc. PBR45 Series Door Access 4.5" Round Push Plate (Push to Open)
- EZ-ACCESS Transitions® Modular Entry Mat
- BEA Inc. PBS45 Series Door Access 4.5" Square Push Plate (Push to Open)
- TownSteel THSP179 Standard Duty Spring Hinge
- Freedom Trax Motorized Track System
- Queue Solutions QueuePro Twin
-
Measures and Procedures
The space for the legs and feet has a fixed dimension of 14.5” deep by 22.5” wide (36.8x57.2cm)....
-
Utilities at Recreation Sites
Place elongated openings more than a quarter of an inch wide with the long dimension perpendicular to the primary direction of travel....
- Guardian Barrier-Free Safety Station with WideArea™ Eye/Face Wash GBF1909PCC
- Lutron Sivoia QED Kirbé Vertical Motorized Drapery System
-
UDI
All dimensions were taken to the extremes of the equipment including any object attached to the device like a ventilator....
- Assisted Living Directory - Connecticut Assisted Living Facilities & Senior Care
-
1008.2.4.1 Ground Level
The clear width of accessible routes shall be permitted to be 36 inches (915 mm) minimum for a distance of 60 inches (1525 mm) maximum provided that multiple reduced width segments are separated...
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
702.1 General
have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1), except that the maximum...
-
11B-405.9 Edge protection
Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½ inch (12.7 mm) maximum within 10 inches (254 mm) horizontally of the minimum landing area...
-
1008.2.4.1 Ground Level
The clear width of accessible routes shall be permitted to be 36 inches (915 mm) minimum for a distance of 60 inches (1525 mm) maximum provided that multiple reduced width segments are separated...
-
608.5.2 Standard Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from...
-
1007.6 Areas of refuge
The maximum travel distance from any accessible space to an area of refuge shall not exceed the travel distance permitted for the occupancy in accordance with Section 1016.1....