Both designs have the potential to reduce the number of available wheelchair seating spaces below the level required. ...
Search Results "Line Spacing (Raised)"
Commonly Searched Documents
-
Section 36.406(f) Assembly Areas (Section-by-Section Analysis)
-
Turning Space: ADA Standard Section 1010.1
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side with a drop off.
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides.
-
Battery-powered Wheelchairs
Battery-powered Wheelchairs You must accept a passenger’s battery-powered wheelchair, including the battery, as checked baggage unless baggage compartment size and aircraft...
-
§ 36.302(f)(5) Hold and release of tickets for accessible seating
(5) Hold and release of tickets for accessible seating.
-
4.1.3(18)
(18) If fixed or built-in seating or tables (including, but not limited to, study carrels and student laboratory stations), are provided in accessible public or common use areas, at...
-
4) Where the Standard is silent about changes in level
4) Where the Standard is silent about changes in level, such as 604.3 around a water closet or in a toilet compartment: Since there is no mention of the phrase "changes in level...
-
3.1.4.2 Width of RV Campsite and Dump Station Vehicle Parking Areas
Where RV camping units or dump stations are provided, vehicle parking areas for recreational vehicles and trailers that are required to be accessible in accordance with table 3.1.1...
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
11B-228.3 Electric vehicle charging stations
[See subsections ...]
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables. At both ends of adult changing tables, clearance...
-
11B-228.3 Electric vehicle charging stations
[See subsections ...]
-
Surface [1017.2]
The surfaces of trails, passing spaces, and resting intervals must be firm and stable. A firm trail surface resists deformation by indentations....
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs....
-
Water Hydrants and Water Spouts [1011.2, 1011.3, and 1011.6]
At water hydrants, a minimum of 72 by 48 inches of clear ground space must be provided with the long side of the space adjoining or overlapping an ORAR or trail as applicable, or another...
- Kohler Elongated Bidet Toilet Seat With In-Line Heater and Touchscreen Remote Control Video
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet....
-
Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
The dashed lines don’t spell it out clearly enough to me....