The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
Search Results "Floor Destination"
Commonly Searched Documents
-
1132A.10 Door signal devices
-
5.8.3.1 Breast Platform Height
The height of the top of the breast platform should be decreased to 26 inches above the floor....
-
11B-608.6 Shower spray unit and water
error by limiting the types of facilities that are allowed to use the vandalism prone area exception and requiring one of the two shower heads to be a maximum of 48 inches above the finish floor...
-
E. Grab Bars
Does each accessible toilet have a horizontal grab bar on the adjacent side wall that is at least 40" long and between 33"-36" above the floor for stabilization and assistance during transfer...
-
F. Grab Bars
Does each accessible toilet have a horizontal grab bar on the wall behind the toilet that is at least 36" long and between 33"-36" above the floor for stabilization and assistance during...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
407.12.3.1 Unobstructed Forward Reach
maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
11B-604.8.3 Coat hooks and shelves
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground....
-
11B.707.7.1.3 Horizontally mounted display screen
from the viewer 60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
- Tile Tech Pavers® Porcelain Pavers™ Series
- Wilkinson Hi-Rise Trash Chute
-
Section 36.404 Alterations: Elevator Exemption (Preamble, Section-by-Section Analysis)
) a building housing five or more sales or rental establishments, or (2) a series of buildings on a common site, connected by a common pedestrian access route above or below the ground floor...
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38, 4.23.9, 4.34.5.3(3)]...
-
11B-804.3.2 Height
The kitchen work surface shall be 34 inches (864 mm) maximum above the finish floor or ground....
-
1007.8.2 Directions
Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the specific story, floor...
-
405.9.2 Curb or Barrier
A curb or barrier shall be provided that prevents the passage of a 4 inch (100 mm) diameter sphere, where any portion of the sphere is within 4 inches (100 mm) of the finish floor or ground...