Through penetrations shall be protected by an approved through-penetration firestop system installed and tested in accordance with ASTM E 814, with a minimum positive pressure differential...
Search Results "Patient in Side-Lying Position"
Commonly Searched Documents
-
711.4.1.2 Through-penetration firestop system
-
12. Staff
.: installing bathtub seats, lowering adjustable shower wands, placing folding seats in transfer showers in the down position, installing auxiliary fire alarm strobes into the building alarm...
- Bobrick B-30929 ClassicSeries® Surface-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
-
Suspicious Minds Ramp
The ramp leading to the exhibits has a rise greater than 6", but does not have the required handrails on both sides. See Standards § 4.8.5. q....
-
5.1.6 Clear Floor or Ground Space
One full unobstructed side of the clear ground space shall adjoin or overlap the trail or ORAR, as applicable, or another clear ground space. ...
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement can be...
-
4.8.5* Handrails
If a ramp run has a rise greater than 6 in (150 mm) or a horizontal projection greater than 72 in (1830 mm), then it shall have handrails on both sides....
-
11B-610.3.1 Rectangular seats
The side edge of the seat shall be 1½ inches (38 mm) maximum from the adjacent wall....
- National Tay-Sachs & Allied Diseases Association (NTSAD)
- Inpro Corporation IPC® 855 Handrail
- Sloan Optima® EHD-401 Sensor Activated Hand Dryer for Surface Mounting
-
904.3.2 Counter
The top of the counter edge protection shall be 2 inches (51 mm) maximum above the top of the counter surface on the aisle side of the check-out counter....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
L. Controls
Are all drapery control wands, fixed lamps and HVAC controls in accessible guestrooms placed within 54" of the floor for side approach or 48" of the floor for forward approach so persons...
-
4.7.11 Islands
Any raised islands in crossings shall be cut through level with the street or have curb ramps at both sides and a level area at least 48 in (1220 mm) long between the curb ramps in the part...
-
§ 38.113(a)(1)
(1) At least one doorway, on each side of the car from which passengers board, of each car required to be accessible by §38.111(a) and where the spaces required by §38.111(d) of this part...
- Bobrick B-30919 ClassicSeries® Surface-Mounted Toilet Tissue, Seat-Cover Dispenser and Waste Disposal
- International Hearing Society (IHS)
- Greenfields Outdoor Fitness Two-Person Accessible Combo Butterfly and Reverse Fly GR2005-1-48E-W (2 Configurations)
- GE Artistry™ Series 30" Free-Standing Electric Range ABS45DFWS
- Stanley QTL 200 Series Grade 2 Standard Duty Tubular Locks
-
Accessible Pool Stairs
Accessible Pool Stairs Accessible pool stairs are designed to provide assistance with balance and support from a standing position when moving from the pool deck into the water and out...