Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1524 mm) wide minimum and shall extend the full length of the boarding pier....
Search Results "Door Clear Width"
-
11B-1003.3.2 Boarding pier clearances
-
1003.3.2 Boarding Pier Clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
-
1003.3.2 Boarding Pier Clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
- Jacknob Corp. 6251 3" High ADA Door Pull Brass-Chrome
- Hager Companies Door Protection Plate 225S
-
Kawneer North America 2000T Terrace Doors
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-604.3.1 Size
ETA Editor's Note The 2013 CBC 11B-604.3 requirement for clearance in front of accessible water closets exceeds the 2010 ADAS requirement, but a door may swing into the added clearance...
-
11B-604.3.1 Size
ETA Editor's Note The CBC 11B-604.3 requirement for clearance in front of accessible water closets exceeds the 2010 ADAS requirement, but a door may swing into the added clearance....
- BEA Inc. PBR45 Series Door Access 4.5" Round Push Plate (Push to Open)
- BEA Inc. EMR475 Series Door Access 4.75" Round Panther Plate (Push to Open)
- BEA Inc. PBS45 Series Door Access 4.5" Square Push Plate (Push to Open)
- BEA Inc. EMS475 Series Door Access 4.75" Square Panther Plate (Push to Open)
-
Position [§305.5]
Position [§305.5] At most elements, clear floor or ground space can be positioned for either a forward or a side approach....
- Rockwood Manufacturing Company 604 Door Guard - Solid Cast Brass
-
T502.2 Doorways with Lifts, Ramps or Bridgeplates
Vertical clearance shall be measured from the inside finished edge of the door opening to the highest point of the deployed lift, ramp or bridgeplate below....
-
1003.3.2 Boarding Pier Clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
-
11B-1003.3.2 Boarding pier clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1524 mm) wide minimum and shall extend the full length of the boarding pier....
- Cavity Sliders USA Inc. CS SofStop™ Insert Track
-
Forward Approach
Forward Approach Clear floor space is required to the face of the unit; a portion can be provided below the unit where clearance is available for toes/knees....
-
408.4.1 Car Dimensions and Doors
408.4.1 Car Dimensions and Doors. Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
11B-1003.3.2 Boarding pier clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1524 mm) wide minimum and shall extend the full length of the boarding pier....
- Corbin Russwin Inc. DC62900 Series Electromechanical Closer-Holder
- Hager Companies Door Protection Plate 220S