42" W x 54" D (107 x 137cm), 1-1/4" (32mm) dia. Constructed of 18-gauge (1.2mm), type 304 satin-finish stainless steel tubing. Concealed mounting flange 1/8" (3mm) thick, type 304...
Search Results "Vertical Grab Bar"
Commonly Searched Documents
- Bobrick Two-Wall Toilet Compartment Grab Bar B-5897
- Bobrick Two-Wall Toilet Compartment Grab Bar B-6897
-
M20
Is there a horizontal grab bar at least 36 inches long securely mounted behind the toilet 33 to 36 inches above the floor with one end no more than 6 inches from the side wall?...
-
H22
Is a second horizontal grab bar at least 36 inches long securely mounted on the back wall with one end no more than 6 inches from the side wall 33 to 36 inches above the floor?...
-
M19
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall?...
- Bobrick 30" Straight Grab Bar B-5806 x 30
- Bobrick 30" Straight Grab Bar B-6806 x 30
-
H21
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall 33 to 36...
-
608.3 Grab Bars (Exception 2)
608.3 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed in shower compartments in residential dwelling units required to provide mobility features...
-
607.4 Grab Bars (Exception 2)
607.4 Grab Bars (Exception 2) Exception 2 to this section permits grab bars to not be installed at bathtubs in residential dwelling units required to provide mobility features provided...
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches long minimum shall be installed on the head end wall at the front edge of the bathtub....
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
California: Toilet Grab Bars - Uneven height allowed?
I noticed that the specific code language suggests that the side grab bar and the rear grab bar must be at the same height (California CBC text is slightly different than ADAS), but it reads...
- Bobrick Two-Wall Toilet Compartment Grab Bar Peened B-6897.99
- Bobrick Two-Wall Toilet Compartment Grab Bar Peened B-5897.99
- Whitehall Mfg. 24" Grab Bar L-Shaped Closure Plate
-
607.4.1.2 Control End Wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
Height
In contrast, Nelson Tremain, in the absence of objective data, rationalized that height of toilet grab bars be based on the distance between the seat and arms of a chair....
-
A4.16.4 Grab Bars
Fig. A6(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet. Some wheelchair users can transfer from the front of the...
-
A4.16.4 GRAB BARS
Fig. A5(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet. Some wheelchair users can transfer from the front of the...
-
607.4.2.3 Head End Wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...
- Bobrick 30" Straight Grab Bar Peened B-5806.99 x 30
- Bobrick 30" Straight Grab Bar Peened B-6806.99 x 30
-
Whitehall Mfg. 24" Grab Bar Flat Closure Plate