Grab bars shall not rotate within their fittings....
Search Results "Vertical Grab Bar"
Commonly Searched Documents
-
11B-609.6 Fittings
- Bradley Security Grab Bars SA70 Series
- AJW Architectural Products UG30-A Series UG30-A12 12" Concealed Set Screw Flange, 1.5" Diameter Grab Bar - Configuration A
- AJW Architectural Products UG20-A Series UG20-A12 12" Concealed Set Screw Flange, 1.25" Diameter Grab Bar - Configuration A
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall....
- Moen Home Care Glacier 12" Grab Bar
- Moen Home Care Peened 12" Grab Bar
-
(5) Reinforced walls for grab bars
The final Guidelines for bathroom wall reinforcement remains essentially unchanged from the Option One guidelines. The only change made to these guidelines has been to subject powder...
-
11B-607.4.1 Bathtubs with permanent seats
For bathtubs with permanent seats, grab bars shall be provided in accordance with Section 11B-607.4.1....
-
11B-607.4.2 Bathtubs without permanent seats
For bathtubs without permanent seats, grab bars shall comply with Section 11B-607.4.2....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
- Bobrick Swing-Up Grab Bar B-4998.99
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
- Mega Jailhouse Anti-Suicide Grab Bar with Closure Plate 42 inches - Concealed Mounting
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...