- Figure 404.2.4.1(d) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Pull Side – Drawing from the U.S. Access Board
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface....
-
11B-204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with Section 11B-307 provided that ground level accessible routes provide vertical clearance in...
-
11B-204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with Section 11B-307 provided that ground level accessible routes provide vertical clearance in...
- Figure 404.2.4.1(i) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Pull Side with Closer – Drawing from the U.S. Access Board
-
M305.3.2 Vertical Position
Where the support is vertical, it shall be 18 inches (455 mm) minimum in length and the bottom end of the support shall be 34 inches (865 mm) high minimum and 37 inches (940 mm) high maximum...
-
5.4 Dining Areas
In non-elevator buildings, an accessible means of vertical access to the mezzanine is not required under the following conditions: 1) the area of mezzanine seating measures no more than...
-
Is additional latch side clearance required on the push side of doors with a forward approach when either a latch or closer (but not both) is provided?
No, latch clearance 12” minimum is required for forward approaches on the push-side of doors equipped with both a closer and a latch....
- Figure 404.2.4.1(g) Maneuvering Clearances at Manual Swinging Doors and Gates: Hinge Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
-
Is vertical access required to all levels of a parking garage?
Vertical access must be provided as necessary to address any changes in level along these required accessible routes....
- Symmetry Vertical Platform Lift VPC-SL
-
407.8.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
407.12.2 Side Reach
The vertical reference plane shall be centered on the operable part and placed at the leading edge of the maximum protrusion of the ICT within the length of the vertical reference plane....
-
Minimum Required Depth: ADA Standard Section 306.2.3
Section 306.2.3 covers the current ADA Standards for the minimum required depth for toe clearance.
-
A4.34.6.1 CLEARANCE
The minimum clearances provide satisfactory maneuvering spaces for wheelchairs only if cabinets are removed at the sink....
-
M303.2.4 Knee and Toe Clearance
Wheelchair spaces shall include knee and toe clearance complying with M303.2.4....
- SafePath EntryLevel™ Landings
-
407.8.2.2 Obstructed Side Reach
Where the operable part is located more than 10 inches (255 mm), but not more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches...
- Symmetry Vertical Platform Lift VPC-EL
-
407.12.2.2 Obstructed Side Reach
Where the operable part is located more than 10 inches (255 mm), but not more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches...
-
Can handrails or other elements overlap door maneuvering clearances?
No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways....
-
M303.2.4 Equipment Clearances
Where wheelchair spaces are entered from the rear and includes space beneath components, wheelchair spaces shall include knee and toe clearances complying with M303.2.4.1 for breast platforms...
-
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis)
407.12.2.2 Obstructed Side Reach (Section-by-Section Analysis) This section proposes that, where the operable part is located more than 10 inches, but not more than 24 inches, behind the vertical...