The Bosch Power Tools GPL 3 is a three-point, self-leveling laser with +/- 1/4 In. accuracy at 100 Ft. for up/down plumb, align and level applications. Unit includes point projection...
Search Results "Slope"
Commonly Searched Documents
- Bosch Power Tools - GPL-3 3 Point Laser
-
Q6.) How important is the method of measurement in considering the tolerances allowable in finished construction?
For ramps and curb ramps, DOJ has issued two technical assistance documents that show how to measure slopes. ...
-
4.3.3 Slope
The slope of tent pads and tent platforms shall not exceed 1:48 (2 percent) in any direction. Exception. ...
-
3.1.3.2 Running Slope (Grade) of Driveways
The running slope of driveways shall be no more than 1:12 (8.33 percent) for no more than 50 feet (15 m). Exception 1....
-
§ 38.23(c)(5) Slope
(5) Slope. Ramps shall have the least slope practicable and shall not exceed 1:4 when deployed to ground level....
-
1009.2.3 Clear Deck Space
The clear deck space shall have a slope not steeper than 1:48....
-
11B-1009.2.3 Clear deck space
The clear deck space shall have a slope not steeper than 1:48....
-
11B-1009.2.3 Clear deck space
The clear deck space shall have a slope not steeper than 1:48....
-
§ 38.83(c)(5) Slope
(5) Slope. Ramps or bridge plates shall have the least slope practicable....
- Starodub, Inc. Ultra-Light Inertial Profiler (ULIP) for Sidewalks
-
1009.2.3 Clear Deck Space
The clear deck space shall have a slope not steeper than 1:48. Figure 1009.2.3 Clear Deck Space at Pool Lifts...
-
11B-1009.2.3 Clear deck space
The clear deck space shall have a slope not steeper than 1:48. FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS...
-
1009.2.3 Clear Deck Space
The clear deck space shall have a slope not steeper than 1:48. Figure 1009.2.3 Clear Deck Space at Pool Lifts...
-
C1-6. Accessible Route Slope
If the slope of part of the accessible route is greater than 1:20, does this part meet the following requirements for an accessible ramp? Yes _____ No _____...
-
Running Slope [1018.7.1]
The running slope of any segment of a beach access route must be no steeper than 1:10 (10 percent)....
-
1.1.5
1.1.5 A maximum design cross slope for accessible exterior pedestrian paving and ramps of 1.5% (1:67 or about 3/16 in. per ft. [15 mm per m]) is recommended....
-
Ramps
Slightly steeper running slopes are permitted for short ramps (maximum 6” rise) where space is limited (§405.2, Ex.)....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
11B-504.4 Tread surface
Exception: Treads shall be permitted to have a slope not steeper than 1:48....
-
11B-504.4 Tread surface
Exception: Treads shall be permitted to have a slope not steeper than 1:48....
- Figure 1009.3.2 Sloped Entry Submerged Depth – Drawing from the U.S. Access Board
-
11B-503.4 Floor and ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
1.2.3 Landings
1.2.3 Landings. Both measurements of ramp landings as described in Section 1.1.15 should not exceed a plus tolerance of 0.5%.