1.1.4 A maximum overall design running slope for exterior accessible ramps of 7.5% (1:13.3 or 1:13) is recommended....
Search Results "Slope"
Commonly Searched Documents
-
1.1.4
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
-
Cross Slope [1016.7.2]
Cross slope is the side-to-side slope of the surface of an ORAR....
- Starodub, Inc. Ultra-Light Inertial Profiler (ULIP) for Sidewalks
-
Sloped Surfaces
One is the running slope that runs parallel to the direction of travel and the other is the cross slope, which runs perpendicular to the running slope....
-
1.1.6 Flatness of walk cross slope
1.1.6 Flatness of walk cross slope....
-
4.1.6(4)(a)
Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises as shown in Table 2 if space limitations prohibit the use of a 1...
-
4.1.6(3)(a)(ii)
(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed....
-
4.1.6(3)(a) Ramps
(a) Ramps: Curb ramps and interior or exterior ramps to be constructed on sites or in existing buildings or facilities where space limitations prohibit the use of a 1:12 slope or less may...
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48....
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48....
-
Changes in Level [4.5.2]
Changes in level ¼ to ½ inch must be beveled with a slope no greater than 1:2....
-
A4.8.1 General
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels. However, some people who use walking aids have difficulty with ramps and...
-
A4.8.1 GENERAL
Ramps are essential for wheelchair users if elevators or lifts are not available to connect different levels. However, some people who use walking aids have difficulty with ramps and...
-
Step 3: Apply the Accessibility Provisions
This step involves looking at FSTAG, sections 7.4.1 through 7.4.8, which contain the technical requirements for trail grade, cross slope, resting interval, surface, clear tread width, passing...
-
4.1.6(3)(a)(i)
(i) A slope between 1:10 and 1:12 is allowed for a maximum rise of 6 inches....
-
1017.7.1 Maximum Running Slope and Segment Length
The running slope of any segment of a trail shall not be steeper than 1:8 (12%). ...
-
1017.7.1 Maximum Running Slope and Segment Length
The running slope of any segment of a trail shall not be steeper than 1:8 (12%)....
-
1.1.11 Ramp running slope
1.1.11 Ramp running slope....
-
7.4.3.1 Running Slope (Grade)
Trail running slope (grade) of up to 1:20 (5 percent) is permitted for any distance....
-
5.1.3 Slope
The slope of the surface of the clear floor or ground space inside the camp shelter shall not be steeper than 1:48 (2 percent) in all directions....
-
2.4.1 Running Slope (Grade)
The running slope (grade) of ORARs shall comply with all applicable provisions of this section. Table 2.4.1....
-
Running Slope [1016.7.1]
Running slope, also referred to as grade, is the lengthwise slope of an ORAR, parallel to the direction of travel....
-
6.7.1 Running Slope (Grade)
The running slope (grade) of a Beach Access Route shall comply with all applicable provisions of this section. Table 6.7.1....