If any obstruction within 18” of the latch side projects more than 8” from the face of a door or gate, maneuvering clearances for a forward approach must be provided....
Search Results "Parallel Approach"
Commonly Searched Documents
-
Recessed Doors and Gates [§404.2.4.3]
-
Minimum Required Depth: ADA Standard Section 306.2.3
Section 306.2.3 covers the current ADA Standards for the minimum required depth for toe clearance.
-
1. New Curb Ramp Construction and Alterations
., a ramp aligned in parallel to the cross-walk) or at least one curb ramp per corner. RT 1978:12-1980:1, 1981:16-1990:19; DTX G07, DTX H04 [000002, 000004]....
-
11B-705.1.2.2.2.1 One entrance/exit point
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
- Just Manufacturing Stainless Steel Cup Strainer ADA Compliant Drain System
- McGuire Manufacturing Co., Inc. 1151AWC: Offset with 151 Stainless Steel Basket Strainer
- McGuire Manufacturing Co., Inc. 155LATWC: Offset Lift and Turn PO Plug
-
B. Question 2: Section 904.4.1 and Clear Counter Space
See 2010 Standards Advisory 904.2 Approach; see also 28 C.F.R. pt. 36 app....
-
9.5.2(2)(d)
(d) at least one common area which a person with mobility impairments can approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
Clear Floor or Ground Space: ADA Standard Section 902.4.1
A clear floor space complying with 305 positioned for forward approach shall be provided....
-
A. Question 1: Applicability of Section 904.4.1’s Exception
Section 904.4.1 and its exception both require that a sales or service counter be “36 inches (915 mm) high maximum above the finish floor,” and Section 904.4.1 further requires that...
-
1011.4.2 Wheelchair Space
Wheelchair spaces shall be positioned for a forward approach to the table and provide knee and toe clearance complying with 306 under the table....
-
1011.4.2 Wheelchair Space
Wheelchair spaces shall be positioned for a forward approach to the table and provide knee and toe clearance complying with 306 under the table....
-
406.4 Landings
Landings shall be provided at the tops of curb ramps. The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb...
-
F208 Parking Spaces
[See subsections ...]
-
III. CONCLUSION
For the foregoing reasons, neither Section 904.4.1 nor its exception requires clear counter space at sales and service counters subject to the ADA’s requirements.
-
1133A.2.1, Item 2
U-shaped kitchens, designed with a cooktop or sink located at the base of the U, which provides a knee and toe space in accordance with Section 1133A.7 to allow for a forward approach, shall...
-
1133A.2.1, Item 2
U-shaped kitchens, designed with a cooktop or sink located at the base of the U, which provides a knee and toe space in accordance with Section 1133A.7 to allow for a forward approach, shall...
-
Raised Work Areas (§203.9)
Raised Work Areas (§203.9) Employee work areas under 300 s.f. that are elevated at least 7” as an essential functional condition of the space (excluding raised courtroom...
-
§ 35.151(b)(4)(ii)
(ii) A path of travel includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
§ 35.151(b)(4)(ii)
(ii) A “path of travel” includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....