Remember that because the clear floor space required by 806.2.3 will be deeper than 24" to end up beside or between the beds where it will be usable, it will be in an alcove that is at least...
Search Results "Imaging Bed"
Commonly Searched Documents
-
Clear floor space beside or between beds must be 36" wide
-
Clear Floor or Ground Space: ADA Standard Section 805.3
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....
-
Transfer Surface (M301.2 and M302.2)
Depending on the configuration of the equipment, the transfer surface may coincide with the seat area of an examination chair, or occupy only a portion of an examination table or imaging...
-
702.3 Association for Information and Image Management (AIIM)
Copies of the referenced standard may be obtained from AIIM,1100 Wayne Ave., Ste. 1100, Silver Spring, Maryland 20910 (http://www.aiim.org/Resources/Standards/AIIM_ISO_14289-1).
-
Tork Image Design™ Matic® Hand Towel Roll Dispenser with Intuition® Sensor
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-805.4.3 Turning space
dated 9/9/14, which includes the following interpretation of Subsections 11B-805.4.1, 11B-805.4.2 and 11B-805.4.3: All patient care areas must provide access to the area and to the bed...
- Tork Image Design S4 466100 Load Refill Video
- Tork Image Design S4 466000 Load Refill Video
-
4. Organization of Technical Criteria
For example, imaging equipment can be designed for use by patients lying on a platform bed, in a standing or seated position, or seated in a wheelchair....
-
Tork Image Design™ Matic® Hand Towel Roll Dispenser with Intuition® Sensor, Recessed Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Question 17
Should the standards be different for adjustable beds, such as hospital beds, and for fixed height beds?...
- Guldmann Mobile Lifter GL5: Lifting from bed to wheelchair
-
Tork Image Design™ Matic® Hand Towel Roll Dispenser with Intuition® Sensor, Recessed CAD Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed and...
-
Hotel Bed Height
Thanks, Kaylan. This is very helpful. I did not know you responded to my question until today. I wish Corada would send an email to alert you that someone responded to your...
- Tork Image Design H2 463002 Wall Mounted Load Refill Video
-
J. Bedside Clearance
Regarding maneuvering space around the bed(s) in the accessible guestrooms... ...in accessible guestrooms with one bed, is there at least a 36" wide route on each side of the bed to allow...
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
806.2.3 Sleeping Areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
6.3(2)
(2) Each one-bed room shall have a minimum clear floor space of 36 in (915 mm) along each side of the bed, and 42 in (1065 mm) between the foot of the bed and the wall....