Changes in level between ¼ inch (6.4 mm) high minimum and ½ inch (12.7 mm) high maximum shall be beveled with a slope not steeper than 1:2....
Search Results "Grade Level Exit"
Commonly Searched Documents
-
11B-303.3 Beveled
-
303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical. Figure 303.2 Vertical Change in Level...
-
303.3 Beveled
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical. Figure 303.2 Vertical Change in Level...
-
11B-303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled....
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADAS] 303.2 Vertical. ...
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADA Standards] 303.2 Vertical....
-
Automatic Operation [4.10.2]
Self-leveling must correct the overtravel or undertravel of a car as it stops at a landing within a ½ inch vertical tolerance since changes in level greater than ½ inch can be troublesome...
-
4.10.2 Automatic Operation
Each car shall be equipped with a self-leveling feature that will automatically bring the car to floor landings within a tolerance of 1/2 in (13 mm) under rated loading to zero loading conditions...
-
4.10.2 AUTOMATIC OPERATION
Each car shall be equipped with a self-leveling feature that will automatically bring the car to floor landings within a tolerance of 1/2 in (13 mm) under rated loading to zero loading conditions...
-
11B-706.6 Peak clipping level
11B-706.6 Peak clipping level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech....
-
6.7.1.2
A grade of up to 1:12 (8.33 percent) is permitted for up to 50 feet (15 m) of a beach access route....
-
6.7.1.3
A grade of up to 1:10 (10 percent) is permitted for up to 30 feet (9 m) of a beach access route....
-
5.3.6 Entrance
The entrance to the toilet shall be level with the surrounding surface....
-
1003.2.13.2 Enclosed stairways
part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area of refuge within an enlarged floor-level...
-
2. Electronic (Digital) Level
Even experts can misjudge how steep a running slope or cross slope is if they do not use a level....
-
303.2 Vertical
Changes in level of 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical....
-
303.4 Ramps
Changes in level greater than ½ inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
303.4 Ramps
Changes in level greater than 1/2 inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
303.4 Ramps
Changes in level greater than ½ inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....