A4.28.3 Visual Alarms
-
4.28.3* Visual Alarms
Visual alarm signal appliances shall be integrated into the building or facility alarm system. If single station audible alarms are provided then single station visual alarm signals...
-
4.28.3(6)
(6) The appliance shall be placed 80 in (2030 mm) above the highest floor level within the space or 6 in (152 mm) below the ceiling, whichever is lower.
-
4.28.1 General
Alarm systems required to be accessible by 4.1 shall comply with 4.28. At a minimum, visual signal appliances shall be provided in buildings and facilities in each of the following...
-
4.28.1 GENERAL
Alarm systems required to be accessible by 4.1 shall comply with 4.28.
-
4.28.3* VISUAL ALARMS
If provided, electrically powered internally illuminated emergency exit signs shall flash as a visual emergency alarm in conjunction with audible emergency alarms. The flashing...
-
A4.28.3 VISUAL ALARMS
The specifications in this section do not preclude the use of zoned or coded alarm systems. In zoned systems, the emergency exit lights in an area will flash whenever an audible...
-
9.2.2(7) Kitchens, Kitchenettes, or Wet Bars
Clear floor space for a front or parallel approach to cabinets, counters, sinks, and appliances shall be provided to comply with 4.2.4....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
Kitchen Appliances and Fixtures
Refrigerator, 2 freezers and pantry for storage to save trips and energy Column refrigerator and freezer offer storage space within reach of shorter people, children,...
-
1133A.7, Item 1
The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided....
-
1133A.7, Item 1
The knee and toe space shall be clear and unobstructed, or removable base cabinets in compliance with Section 1133A.3 shall be provided....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
Visible Alarms in Alterations to Existing Facilities
Section 215.1 of the 2010 Standards adds a new exception to the scoping requirement for visible alarms in existing facilities so that visible alarms must be installed only when an existing fire...
-
OCCUPANT NOTIFICATION SYSTEMS
People who are blind or have low vision can hear standard building fire alarms and voice announcements over public address systems that warn of a danger or the need to evacuate or that provide...
-
F215.1 General
Where fire alarm systems provide audible alarm coverage, alarms shall comply with F215....
-
215.1 General
Where fire alarm systems provide audible alarm coverage, alarms shall comply with 215....
-
215.1 General
Where fire alarm systems provide audible alarm coverage, alarms shall comply with 215....
-
4.2.1 General
Where fire rings, grills, fireplaces, or woodstoves are provided, each shall comply with section 4.2. Exception....
-
OCCUPANT NOTIFICATION SYSTEMS
However, the ability of a person with a cognitive disability to recognize and understand a fire alarm or other emergency notification systems and what they mean should be verified....
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying with...
-
Clear Floor or Ground Space: ADA Standard Section 804.3.1
A clear floor space complying with 305 positioned for a forward approach shall be provided. The clear floor or ground space shall be centered on the kitchen work surface and shall...
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. The clear floor or ground space shall be centered on the kitchen work surface...