Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)] Clear floor space for either a forward or a side approach is permitted for cabinets, counters, sinks, and appliances....
Search Results "FEC: Fire Extinguisher Cabinet"
Commonly Searched Documents
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
-
[2010 ADAS] 105.2.5 NFPA
Copies of the referenced standards may be obtained from the National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02169-7471, (http://www.nfpa.org)....
-
907.2.3 Group E
A manual fire alarm system shall be installed in Group E occupancies....
-
11B-215 FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS
[See subsections ...]
-
11B-215 Fire alarm systems and carbon monoxide alarm systems.
[See subsections ...]
-
907.1.2 Equipment
Systems and their components shall be listed and approved for the purpose for which they are installed.
-
[F] 907.5 Occupant notification systems
[F] 907.5 Occupant notification systems. ...
-
III-7.5160 Alarms
III−7.5160 Alarms (ADAAG §4.1.3(14)). Both audible and visual alarms are required when emergency warning systems are provided. ADAAG has detailed requirements concerning features...
-
[F] 907.5 Occupant notification systems
...
-
Visual Alarms
Visual Alarms • Where audible fire alarms or emergency notification is provided, flashing lights are required in public and common use areas, including toilet and bath rooms, locker rooms...
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
-
Technical Memorandum TM 2013-23 Storage (Not in Kitchens or Kitchenettes)
Access Board, “type” refers to the design of the element (i.e. closets, cabinets, shelves, clothes rods, hooks, and drawers) as well as the intended use (i.e. coat closets, supply closets...
- American Specialties Recessed Specimen Pass-Through Cabinet 8154
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter...
-
American Specialties Recessed Specimen Pass-Through Cabinet Model 8154
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor.
- Bobrick Recessed Heavy Duty Specimen Pass-Through Cabinet B-50517
- Bobrick Recessed Heavy Duty Specimen Pass-Through Cabinet B-50516
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
1010.1 Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
1010.1 Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....