Where provided, elevators shall comply with 4.10. Elevators or other accessible means of vertical movement are not required in residential facilities when: (a) No accessible...
Search Results "Exit Enclosure"
Commonly Searched Documents
-
4.1.3(1) ELEVATORS
-
11B-216.1 General
New or altered signs shall be provided in accordance with Section 11B-216 and shall comply with Section 11B-703. The addition of or replacement of signs shall not trigger any...
-
Determine All Your Evacuation Options and Prioritize Them
OUT You and/or your helpers may be injured in the process Use of Evacuation Chairs Fold up chairs, which can be stored near emergency exits...
-
Mounting Location and Height [4.30.6]
., illuminated exit signs overhead) redundancy is required....
-
11B-809.8.3 Door maneuvering clearance.
At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2....
-
Finish and Contrast: ADA Standard Section 703.5.1
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
11B-703.5.1 Finish and contrast
Characters and their background shall have a non-glare finish. Characters shall contrast with their background with either light characters on a dark background or dark characters on...
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall comply with Section 11B-705.1.2.2.
-
III-7.5165 Signage
. , men's and women's rooms, room numbers, exit signs) must have raised and Brailled letters; must comply with finish and contrast standards; and must be mounted at a certain height and...
-
Are employee restrooms and break rooms required to be accessible?
Areas used only by employees for work are not required to be fully accessible but must be connected by accessible routes and means of egress for approach, entry, and exit and have wiring...
-
Employee Work Areas [§203.9]
At a minimum, areas used only by employees as work areas must meet requirements for: access to approach, entry, and exit the work area (§203.9) accessible means of egress...
-
Case: ADA Standard Section 703.5.2
Characters shall be uppercase or lowercase or a combination of both.
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
11B-703.5.2 Case
Characters shall be uppercase or lowercase or a combination of both.
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due...
-
11B-203 General exceptions
shall only be required to comply with Sections 11B-206.2.8, 11B-207.1, and 11B-215.3 and shall be designed and constructed so that individuals with disabilities can approach, enter, and exit...
-
F216 Signs
[See subsections ...]
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
11B-703 SIGNS
[See subsections ...]
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60...
-
703 Signs
Requirements for signs provide specifications for raised characters (703.2), braille characters (703.3), the height and location of signs with tactile characters (703.4), visual...
-
Mounting Height and Location
Section 703.4 covers the mounting height and location of signs with tactile characters. Such signs are to be mounted so that the tactile elements (raised characters and braille) are...