Under §104.44(d), a recipient must ensure that no handicapped student is subject to discrimination in the recipient's program because of the absence of necessary auxiliary educational aids...
Search Results "Auxiliary Alarm"
-
31. Academic adjustments
-
12. How does a parent request auxiliary aids and services for a child under Title II? Can the request be made as part of the IEP process or must it be made through a separate process?
The school district can determine whom the parent should contact with requests for auxiliary aids and services and other ADA issues....
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter...
-
1. Under Title II, what must public school districts do to provide effective communication to students with hearing, vision, or speech disabilities?
To do this, public schools must provide appropriate “auxiliary aids and services” where necessary to provide effective communication;20 that is, schools must provide appropriate auxiliary...
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm signal...
- Safety Technology: the First 30 Years
-
4.1.3(14)
(14) If emergency warning systems are provided, then they shall include both audible alarms and visual alarms complying with 4.28....
-
907.2.6.2.1 System initiation
Actuation of an automatic fire-extinguishing system, a manual fire alarm box or a fire detector shall initiate an approved fire alarm signal which automatically notifies staff....
-
B. Legal Authority to Require Captioning and Audio Description
[See subsections ...]
-
907.2.8 Group R-1
A manual fire alarm system and an automatic fire detection system shall be installed in Group R-1 occupancies....
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
806.3.1 Alarms
806.3.1 Alarms. Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
A. Non-Discrimination
. § 36.302; Atlantis will furnish appropriate auxiliary aids and services, free of charge, when necessary to ensure effective communication with individuals with disabilities...
-
4.28.3(7)
(7) In general, no place in any room or space required to have a visual signal appliance shall be more than 50 ft (15 m) from the signal (in the horizontal plane). In large rooms and...
-
4.28.3(6)
(6) The appliance shall be placed 80 in (2030 mm) above the highest floor level within the space or 6 in (152 mm) below the ceiling, whichever is lower.
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
1.1.3.2, Item 14.3
Fire alarm devices, equipment and systems in connection with any occupancy....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
702 Fire Alarm Systems
702 Fire Alarm Systems...
-
907.2.6.2 Group I-3
Group I-3 occupancies shall be equipped with a manual and automatic fire alarm system installed for alerting staff....
-
Location: ADA Standard Section 407.4.6.4.2
Section 407.4.6.4.2 covers the current ADA Standards for the location of the emergency controls in elevator cars.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel....