Public entities are required to “make available appropriate auxiliary aids and services where necessary to ensure effective communication.”...
Search Results "Auxiliary Alarm"
Commonly Searched Documents
-
Do all print materials need to be available in large print and Braille or are they only required upon request?
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
5. Do Title II and Section 504 apply to the programs, services, and activities of family courts?
Courts are required to provide auxiliary aids and services when necessary to ensure effective communication, unless an undue burden or fundamental alteration would result.60 For example...
-
4.28.3(7)
(7) In general, no place in any room or space required to have a visual signal appliance shall be more than 50 ft (15 m) from the signal (in the horizontal plane). In large rooms and...
-
4.28.3(6)
(6) The appliance shall be placed 80 in (2030 mm) above the highest floor level within the space or 6 in (152 mm) below the ceiling, whichever is lower.
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
1.1.3.2, Item 14.3
Fire alarm devices, equipment and systems in connection with any occupancy....
-
702 Fire Alarm Systems
702 Fire Alarm Systems...
-
907.2.6.2 Group I-3
Group I-3 occupancies shall be equipped with a manual and automatic fire alarm system installed for alerting staff....
-
Location: ADA Standard Section 407.4.6.4.2
Section 407.4.6.4.2 covers the current ADA Standards for the location of the emergency controls in elevator cars.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel....
-
Location and Spacing
Provisions for the spacing of visual alarms in hallways and corridors generally require one fixture every 100 feet....
-
907.2.6 Group I
A manual fire alarm system and an automatic fire detection system shall be installed in Group I occupancies....
-
806.3.1 Alarms
Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
806.3.1 Alarms
Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
4. What factors should a public school district consider in determining what auxiliary aids or services are necessary to afford qualified students with disabilities an equal opportunity to participate in, and enjoy the benefits of, the public school’s services, programs, or activities?
The determination of what auxiliary aids or services will provide effective communication must be made on a case‐by‐case basis, considering the communication used by the student, the nature...
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.3, and carbon monoxide alarms, where provided, complying with...
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying with...
-
809.5.1 Building Fire Alarm System
809.5.1 Building Fire Alarm System....
-
Chapter 3 General Effective Communication Requirements Under Title II of the ADA
What are auxiliary aids and services? When is a state or local government required to provide auxiliary aids and services?...
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying with...
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....