Access Board 2012 Notice of Proposed Rule Making M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position M302...
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
1.3.1 Overview of NPRM
-
Accessible Medical Equipment
Importance of Accessible Examination Tables, Chairs and Weight Scales http://www.hfcdihp.org/products Exam Room Selection for Accessible Examination Tables & Chairs PDF...
-
25. Please indicate the date (year) of trail surface installation
Please indicate the date (year) of trail surface installation:...
-
Expert Advice of Medical Practitioners
Expert Advice of Medical Practitioners Numerous practitioners commented on the importance of the availability of a lower transfer surface. Nüket J....
-
1134A.5, Item 1
There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to provide for the maneuvering...
-
1134A.5, Item 1
There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to provide for the maneuvering...
-
1.3.2 Focus Following NPRM Comments
This review identified four major issue areas for the MDE Advisory Committee to address, as follows: Transfer surface height and size Permitted obstructions to the transfer surface...
-
What values are recommended for ground and floor surfaces along an accessible route?
What values are recommended for ground and floor surfaces along an accessible route?...
-
Features of an Accessible Examination Room
A clear floor space, 30” X 48” minimum, adjacent to the exam table and adjoining accessible route make it possible to do a side transfer. 2....
-
Water closet
Additional space between the sidewall and the water closet was intended to provide space on both sides of the fixture for a caregiver to stand alongside....
-
DSA Drawing 11B-406-3 Perpendicular Curb Ramp next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
ALIGNMENT OF 19-INCH RECOMMENDATION WITH ACCESS BOARD PROPOSED RULEMAKING
In its proposed rule, the Access Board proposed that the “height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured...
-
Bradley Surface Mounted Stainless Steel Single Roll Toilet Tissue Dispenser 5084 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Wheelchair Space for Seat Transfer
Comment. The proposed rule specified that the wheelchair space be positioned so that it provides a parallel approach to an end of the bench seat (903.2). Commenters indicated that...
-
Durability and Maintenance of Detectable Warning Surfaces (Section-by-Section Analysis)
Durability and Maintenance of Detectable Warning Surfaces (Section-by-Section Analysis) Transportation officials who commented on the 2002 draft guidelines expressed concern about the...
- AJW Architectural Products U719 96"W x 48"H J-Mold Mirror - Four Sided Frame - Plate Glass
-
G. Sleeping Areas
Accessible cots have a sleeping surface at approximately the same height above the floor as the seat of a wheelchair (17 to 19 inches above the floor)....
-
Conclusions
Conclusions The proposed guidelines for medical diagnostic equipment currently recommend a minimum transfer surface 30 in. (760mm) wide and 15 in. (381mm) deep....
-
34. Please indicate the condition of the trail’s surface characteristics within the last quarter
Please indicate the condition of the trail’s surface characteristics within the last quarter (choose all that apply): Trail’s Surface Characteristics Choose all that apply...
- Allegion LCN 1460 Series Surface Mounted Door Control
-
Medical Diagnostic Equipment: ADA Standard Section 5.
Review the updated information on the revisions to the ADA Standards regarding medical diagnostic equipment.
-
SEAT HEIGHT MEASUREMENT DETAIL
Measuring to the top of the bolster would account for the maximum transfer height differential from a wheeled mobility device....
- Forms + Surfaces Summit Bike Rack
-
What is a good un-official "working" definition of "work surface"?
11B-805.7 goes on to list numerous items that would/could be included in the broad verbiage of "Built-in cabinets, counters and work surfaces"....