., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (101.6 mm)....
Search Results "Seat Height"
-
1132A.4, Item 3
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum. The surface of the bottom tread shall extend to a water depth of 18 inches (457 mm) minimum below the stationary water level....
-
11B-1009.5.4 Transfer steps
Transfer step height shall be 8 inches (203 mm) maximum....
-
11B-505.3 Continuity
Exception: In assembly areas, ramp handrails adjacent to seating or within the aisle width shall not be required to be continuous in aisles serving seating....
-
11B-505.3 Continuity
Exception: In assembly areas, ramp handrails adjacent to seating or within the aisle width shall not be required to be continuous in aisles serving seating....
-
T303 Handrails, Stanchions, and Handholds
We received only one comment on the proposed technical requirements in the 2010 NPRM related to the cross section of seat-back handholds....
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
Location of Accessible Routes to Stages
The 1991 Standards at section 4.33.5 require an accessible route to connect the accessible seating and the performing area....
-
Is obesity considered a disability under the ACAA?
QUESTION: Is obesity considered a disability under the ACAA and, if so, is an obese passenger entitled to two seats for the price of one if he or she needs more than one seat?...
-
§ 38.23(d)(2) Location and size
Not more than 6 inches of the required clear floor space may be accommodated for footrests under another seat provided there is a minimum of 9 inches from the floor to the lowest part of...
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
904 Sales and Service Counters
Specifications are provided for the counter surface height of check-out aisles, including the height of counter edge protection, which is limited to 2 inches above the counter surface (904.3.2...
-
You must allow passengers to safely stow their wheelchairs
., wheels, seats, etc.) in the overhead bin or under seats. [Sec. 382.41(e)(1)]...
-
Substantive changes made to requirements for elevators
Substantive changes made to requirements for elevators in section 407 include: revision of the height of call controls (407.2.1.1) removal of a specification concerning...
-
211 and 602 Drinking Fountains
The 1991 Standards require wall and post-mounted cantilevered drinking fountains mounted at a height for wheelchair users to provide clear floor space for a forward approach with knee and...
-
BENEFITS AND COSTS: OVERVIEW
BENEFITS AND COSTS: OVERVIEW Based on our analysis, we determined that transfer surface height requirements lower than 19 inches would increase the cost of designing and manufacturing...
-
407.12.3 Forward Reach (Section-by-Section Analysis)
This section proposes to limit the height of an obstruction that must be reached over to operate the control to 34 inches in height....
-
ASME
This document does not permit the use of inclined stairway chairlifts which do not provide platforms because such lifts require the user to transfer to a seat....
-
11B-219.3 Receivers
The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two....
-
Ticket pricing. (Section-by-Section Analysis)
Accessible seating must be made available at all price levels for an event. ...
-
11B-505.3 Continuity
Exception: In assembly areas, ramp handrails adjacent to seating or within the aisle width shall not be required to be continuous in aisles serving seating....
-
11B-612.2 Bench
Where seating is provided in saunas and steam rooms, at least one bench shall comply with Section 11B-903....
-
11B-612.2 Bench
Where seating is provided in saunas and steam rooms, at least one bench shall comply with Section 11B-903....
-
11B-303.5 Warning curbs
(102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning curbs at least 6 inches (152 mm) in height...