booth in durable plastic suitcase Lightweight, 10/lb unit All components packaged in custom box Rugged blow molded lid and base Durable blow molded plastic side...
Search Results "Pull Side"
Commonly Searched Documents
- Inclusion Solutions Model 2000 Voting Booth (Hard Curtain)
- Nova Health Products LiteRamp 2' Wheelchair and Scooter Ramp (LR2)
- Nova Health Products LiteRamp 4' Wheelchair and Scooter Ramp (LR4)
- Nova Health Products LiteRamp 3' Wheelchair and Scooter Ramp (LR3)
- DEL Automated Blinds and Electric Blinds
- Adaptive Engineering Inc. Mobilift CX Wheelchair Lift
-
4.3.4 Knee and Toe Clearances
Hence, to accommodate a particular percentage of users, the side profile of a design element (shown by dotted line) should not extend outside the corresponding shaded area....
-
4.3.3 Clear Floor Area
For example, when designing an alcove at the side of a large open space where the length of a device must be addressed but the width is not an issue because there is plenty of room to one...
- Activar JL Industries Cosmopolitan Series 2035S21 Stainless Steel Fire Extinguisher Cabinet
- Haws AXION® MSR Barrier-Free Recessed Eye/Face Wash
- Besam SW100 Low Energy Swing Door Operator
- American Specialties 9013 Recessed Stainless Steel Baby Changing Station
-
2. Equipment Clearances for Breast Platforms
The knee and toe clearance requirements were adopted from the 2004 ADA and ABA Accessibility Guidelines and typically will allow a person seated in a wheelchair to pull underneath a work...
-
Periodic Reevaluation of Students with Disabilities
days and create a pattern of removal.77 OCR also considers a school’s transferring a student from one type of program to another (for example, from a general education class with pull-out...
-
1134A.2 Number of complying bathrooms
A minimum 18-inch (457 mm) clear maneuvering space shall be provided on the swing side of the door at the strike edge of the door. 9. ...
-
1134A.2 Number of complying bathrooms
A minimum 18-inch (457 mm) clear maneuvering space shall be provided on the swing side of the door at the strike edge of the door. 9....
-
Section 1193.37 Information pass-through [1193.27 in the NPRM] (Section-by-Section Analysis)
In addition, manufacturers objected to the one-sided nature of the requirement and wanted manufacturers of peripheral devices and specialized customer premises equipment to be held accountable...
-
Designated Aisle Seats
a) of the 1991 Standards requires one percent (1%) of fixed seats in assembly areas to be designated aisle seats with either no armrests or folding or retractable armrests on the aisle side...
-
Exercise Equipment and Machines
If the clear space is enclosed on three sides (e.g., by walls or the equipment itself), the clear space must be at least 36 by 48 inches....
-
5.9.1 Standing Supports Recommendation In Reference To Mammography Equipment
Rationale for recommendation The original criteria proposed in the NPRM included vertical standing supports on both sides of the equipment that were 18 inches in length....
-
Passing Spaces [1016.4]
T-shaped space extend a minimum of 48 inches beyond the intersection (figure 12) Either of these configurations provides enough space for people using mobility devices to move to the side...
-
Standing Supports [M305.2]
Rationale The original criteria proposed in the NPRM included vertical standing supports on both sides of the equipment that were 18 inches in length....
-
Requirement 6. Reinforced walls for grab bars.
Where the toilet is not placed adjacent to a side wall, the bathroom would comply if provision was made for installation of floor mounted, foldaway or similar alternative grab bars....
-
Alternative Designs. Bathroom as Shower Room
This turned out not to be the case, and a retrofit with an after-market in-line valve installed on the upstream side of the coupling turned out to be impractical due to the danger of backflow...