Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
Search Results "Ground Floor"
-
11B-307.2 Protrusion limits
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
Section 2. Definitions
New terms defined in the final Guidelines include: "adaptable," "assistive device," "ground floor," "loft," "multistory dwelling unit," "single-story dwelling unit," and "story"....
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
Re: Lavatories Adjacent to Partitions
Were the CBC requirement instead made a part of 11B-606.2 (Clear Floor Space), I suppose we'd have to give the notion of "clear" some more thought. ...
-
Winning the War: Bamboo and Invasive Removal with the X500
You can use the edge of the bucket to leverage large clumps of rhizomes out of the ground....
- Hill-Rom Liko® M220 / M230 Mobile Lift, Senior Video
- Mayer-Rothschild Foundation: Determination of Grab Bar Specifications for Independent and Assisted Transfers in Residential Care Settings
-
Circulation Paths
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
SHOPPING CENTER (OR SHOPPING MALL)
A shopping center may include a series of buildings on a common site, connected by a common pedestrian access route on, above or below the ground floor, that is either under common ownership...
-
Design Opportunity
27" AFF under the vanity top (306) while keeping the counter/rim at 34" AFF maximum (606.3); and it may require more than 8" minimum knee clearance to provide the extended depth clear floor...
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-
Non-Positive Shut-off
Remember that the hose has to be at least 59" long so it would fall onto the floor of the tub if dropped. It's a plumbing safety requirement....
-
Use Zone
The ground level area beneath and immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 (incorporated by reference, see “Referenced Standards” in Chapter...
-
Reach Ranges
The 1991 Standards set the maximum height for side reach at 54 inches above the floor....
-
Gaps: ADA Standard Section 1002.4.3
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
- Indiana AgrAbility
-
Wheelchair Accessible Telephones: ADA Standard Section 217.2
Section 217.2 covers scoping requirements in the current ADA Standards for wheelchair accessible telephones.
-
FIGURE INDEX
FIGURE INDEX Figure 104 Graphic Convention for Figures Figure 302.2 Carpet Pile Height Figure 302.3 Elongated Openings in Floor or Ground Surfaces Figure 303.2 Vertical Change...