gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
Search Results "Floor Destination Indicator"
-
11B-404.2.11 Vision lights
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
11B-608.5.2 Standard roll-in type shower compartments
the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-608.5.2 Standard roll-in type shower compartments
the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...
-
Forward Approach: ADA Standard Section 904.4.2
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Fur out the wall
Don't cut the concrete or flooring or move plumbing. Just need to make sure all other clearances, (42" from center line to adjacent wall/fixture is clear, etc.) ...
-
California: Toilet Grab Bars - Uneven height allowed?
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
Sales Counters
Exception 1 indicates that sales and service counters, which are addressed in section 227 (Sales and Service), are not required to comply with the requirements for dining and work surfaces...
-
Set the Automatic Volume Adjustment
It might be necessary to readjust the volume of the locator tone and Walk indications after the microphone or “dB over ambient” setting is adjusted....
-
Legal Requirements and Customer Service
Words such as “should” or “may” indicate accommodations that part 382 does not require but that DOT recommends and that you may decide to provide as a matter of good customer service....
-
4.3.11.5 Identification
Signage shall also be installed at all inaccessible exits and where otherwise necessary to clearly indicate the direction to areas of rescue assistance....
-
216.6 Entrances
Directional signs complying with 703.5 that indicate the location of the nearest entrance complying with 404 shall be provided at entrances that do not comply with 404....
-
5.8.2.7 Base Support Allowance Recommendation
of 4 inches above the floor at a depth of 28 inches from the front edge of the breast platform....
-
6) Water fountains
6) Water fountains ADAAG: Where there is more than one fountain on a floor, 50% must be accessible to persons using wheelchairs....
-
Height: ADA Standard Section 407.2.1.1
Section 407.2.1.1 covers the current ADA Standards for the height of the elevator call controls.
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
Flush Controls: ADA Standard Section 604.9.5
Section 604.9.5 covers the current ADA Standards for flush controls on children's use water closets.
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
223 Medical Care and Long-Term Care Facilities
This section indicates the number of patient or resident sleeping rooms required to be accessible in medical care and long-term care facilities....
-
212 Sinks, Kitchens, and Kitchenettes
These exceptions have been removed as unnecessary since scoping elsewhere in Chapter 2 indicates the number of rooms, units, and cells required to be accessible....