Anyone in the Office or Building People with limited mobility who are able to go up and down stairs easily but have trouble operating door locks, latches, and other devices due to limitations...
Search Results "Door Swing"
-
Who Will Provide the Assistance?
-
How to Use this Checklist
Gather Tools Checklist Clipboard makes it easier to write on the checklist Tape measure Electronic or carpenter’s level - 24 inches Door pressure...
-
Typical Issues
An accessible entrance must provide at least one accessible door with maneuvering space, accessible door hardware, and enough clear width to allow people who use crutches, a cane, walker...
-
16(a)(iii)
§ 9.3 may be achieved by either providing (1) visual alarms that are connected to the building emergency alarm system, and visual notification devices for incoming telephone calls and door...
-
D5. Raised Threshold
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
A4.2.1(3) Space Requirements for Passing
Able-bodied persons in winter clothing, walking straight ahead with arms swinging, need 32 in (815 mm) of width, which includes 2 in (50 mm) on either side for sway, and another 1 in (25...
-
A4.2.1(3) Space Requirements for Passing
Able-bodied people in winter clothing, walking straight ahead with arms swinging, need 32 in (815 mm) of width, which includes 2 in (50 mm) on either side for sway, and another 1 in (25...
-
Developing a plan based on priorities
Priority 1: Getting through the Door The first priority is to make sure individuals with disabilities can physically enter the facility as independently as possible....
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Application Based on Building or Facility Use: ADA Standard Section 201.2
Section 201.2 covers the application of the most current requirements based on the building or facility use.
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.9 at doors to areas of refuge and exterior areas for assisted rescue shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5...
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1009.9 at doors to areas of refuge and exterior areas for assisted rescue shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5...
-
g-v
If the answers to questions g-ii thru g-iv are No, can the door be propped open? ...
-
11B-245.3 Accessible elements required
The accessible portion of the residence extends to those elements used to enter the commercial facility, including the front sidewalk, if any, the door or entryway, and hallways; and those...
-
11B-245.3 Accessible elements required
The accessible portion of the residence extends to those elements used to enter the public accommodation, including the front sidewalk, if any, the door or entryway, and hallways; and those...
-
11B-245.3 Accessible elements required
The accessible portion of the residence extends to those elements used to enter the commercial facility, including the front sidewalk, if any, the door or entryway, and hallways; and those...
-
Water Closet Clearance
requirements of section 604.3 of the 2010 Standards because of the significant reconfiguration and reconstruction that would be required, such as moving plumbing fixtures, walls, and/or doors...
-
502.2.1 On-street parallel parking
Curbs adjacent to such spaces must be of a height that does not interfere with the opening and closing of motor vehicle doors. Figure 502.2 Vehicle Parking Spaces...
-
4.3.3 Width
The minimum clear width of an accessible route shall be 36 in (915 mm) except at doors (see 4.13.5 and 4.13.6)....
- ADA Sign Depot Elevator Door Jamb Floor Level Braille Sign - 4" x 4" - Tactile Sign
- Spectrum Industries Inc. Instructor Media Console and Workstation
-
Sec.36.304(c)(3)
These measures include, for example, removal of obstructing furniture or vending machines, widening of doors, installation of ramps, providing accessible signage, widening of toilet stalls...
-
11B-216.4.4 Delayed egress locks
Signs required by Chapter 10, Section 1008.1.9.7, item 5.1 at doors with delayed egress locks shall comply with Sections 11B-703.1 _|Signs; General|_ 11B-703.2 _|Signs; Raised Characters...
-
14.3 Q...are there any requirements for the inside dimensions of these individual parking garages?
Therefore, at least two percent of the garages should be at least 14'2 wide and the vehicular door should be at least 10'-0 wide....