For example, an elevator of 47 in by 69 in (1195 mm by 1755 mm) with a door opening on the narrow dimension, could accommodate the standard wheelchair clearances shown in Figure 4....
Search Results "Clear Opening"
-
4.1.6(3)(c)(iii)
-
D3. Door Hardware
[ADA Stds 4.13.9] Yes _____ No _____ If No, leave door propped open, add new accessible hardware, or adapt/replace hardware....
-
5b.
[ADA Stds 4.10.9] Note: See Figure 22 for acceptable floor and opening dimensions....
-
Scoping [4.1.3(5)]
elevators only in providing access to: performing areas in assembly occupancies wheelchair seating locations in assembly occupancies incidental space or rooms not open...
-
11B-611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (381 mm) minimum and 36 inches (914 mm) maximum above the finish floor....
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar, with the opening of the disposal unit 19” minimum (483 mm) above the finish floor....
-
§ 38.119(b)
(b) The doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 foot-candle of illumination on the station...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-608.5.1 Transfer type shower compartments
mm) minimum and 48 inches (1219 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline of the seat toward the shower opening...
-
608.5.1 Transfer Type Shower Compartments
mm) minimum and 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) maximum from the centerline of the seat toward the shower opening...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
211 and 602 Drinking Fountains
The 1991 Standards require wall and post-mounted cantilevered drinking fountains mounted at a height for wheelchair users to provide clear floor space for a forward approach with knee and...
-
407.8.3.2.2 Knee and Toe Space under ICT with Obstructed Forward Reach
Knee and toe space under ICT shall be 27 inches (685 mm) high minimum, 25 inches (635 mm) deep maximum, and 30 inches (760 mm) wide minimum and shall be clear of obstructions....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
§ 38.159(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches (1220 mm)....
-
7. Commit to Ongoing Maintenance of Accessible Playground Surfaces as a Responsibility of Ownership
This will require the surface material to be raked level, filled and compacted so that the clear ground space is level in all directions for a safe transfer onto and off the equipment....
-
Sales and Service Counters: ADA Standard Section 904.4
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
11B-809.7 Accessible routes
The accessible route shall adjoin or overlap clear floor spaces and connect all exterior doors....
-
11B-1008.4.3 Play tables
Exception: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
11B-809.7 Accessible routes
The accessible route shall adjoin or overlap clear floor spaces and connect all exterior doors....
-
11B-1008.4.3 Play tables
Exception: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required...
-
R308.1 Transit Stops
Where security bollards are installed at transit stops, they must not obstruct the clear space at boarding and alighting areas or reduce the required clear width at pedestrian access routes...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...