(b) The doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 footcandle of illumination on the station platform...
Search Results "Clear Opening"
-
§ 38.101(b)
-
§ 38.157(b)
(b) The vehicle doorway shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination on the pathway to the door for a distance of 3 feet (915...
-
11B-611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (381 mm) minimum and 36 inches (914 mm) maximum above the finish floor....
-
604.9.5 Flush Controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with 604.8.2....
-
611.4 Height
Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches (380 mm) minimum and 36 inches (915 mm) maximum above the finish floor....
-
B. Legal foundation for captioning and video description
Filmmakers, are, however, encouraged to produce and distribute open-captioned versions of films, and theaters are encouraged to have at least some pre-announced screenings of a captioned...
-
R406.3 Unobstructed Side Reach
Where a clear space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380...
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
11B-604.6 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
§ 36.303(f)(3)
(3) A clear, audible transmission of voices; and...
-
§ 35.160(d)(3)
(3) A clear, audible transmission of voices; and...
-
Free Tax Dissertation Topics Service – Expert Research Ideas for Your Academic Success
Before, I struggled to find clear and relevant ideas, but this service provided focused, up-to-date, and researchable topics....
-
Getting From Here to There—Outdoor Recreation Access Routes
Design outdoor recreation access routes to meet technical requirements for running and cross slopes, resting intervals, surface, clear tread width, passing spaces, tread obstacles, protruding...
-
603 Toilet and Bathing Rooms
Section 603 covers toilet and bathing rooms and includes requirements for clear floor space, wheelchair turning space, permitted overlaps of various space requirements, and doors....
-
§1630.1(a) Purpose
The ADA as amended, and these regulations, are intended to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities,...
- Access Board: Signs
-
Microsoft Word implementation
Right click the image and select Size… Open the Alt Text Tab and type in the appropriate alt-text....
-
e-ii
[ADA Standards § 4.10.9, Fig. 22] Yes No Note: See Figure 22 for acceptable floor and opening dimensions....
-
C.8 - Are Section 508 access requirements satisfied if the agency provides such access following a request for it, as opposed to in anticipation of a request for access?
For example, the production of a training video, which is covered by the Section 508 standards, must include the incorporation of open or closed captioning and audio description during the...
-
E. Key Reach Range
If there is key card controlled door hardware on building entrances, is the key card reader positioned so persons who use wheelchairs may approach and operate the opener (48" high maximum...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
1008.1.9.7, Item 5
THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM WILL SOUND” Sign lettering shall be at least 1 inch (25 mm) in height and shall have a stroke of not less than 1/8 inch (3.2 mm)....