When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
Search Results "Ground Floor Exit"
-
11B-602.9 Pedestrian protection
-
Area of Refuge Identification [IBC §1007.6.5 (2003), §1003.2.13.5.5 (2000)]
Sample Area of Refuge and Exit Sign Areas of refuge are not required in facilities that are equipped throughout with an automated sprinkler systems in compliance with the IBC...
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
4.5.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-904.4 Sales and service counters
number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor...
-
11B-904.4 Sales and service counters
number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear floor...
-
2. What does the ADA require for accessibility of pools?
The Standards also provide technical specifications for when a means of entry is accessible, such as, for pool lifts, the location, size of the seat, lifting capacity, and clear floor space...
- Scranton Toilet Partitions: Eclipse - Floor Mount Headrail
-
Swanstone Barrier-Free Shower Floor FBF-3464